Comem L140; Comem Oli / Eoli - ABB Comem OLI Instruction Manual

Liquid level indicator
Table of Contents

Advertisement

L I Q U I D L E V E L I N D I C AT O R - INSTRUCTION MANUAL
14
4. Installation
4.3
Insert the arm with float through the machined hole
on the conservator. Place the o-ring on the slot
behind the gauge. Insert the device on the threaded
pin of the conservator flange (Fig.17/A). The oil level
indicator has to be mounted using the items
(Fig.17/B) showed in the table 4b.
Q.ty
6
6
6
1
Table 4b
A
Figure 17

Comem L140

Description
Reference standard
Ø6 plane washer
UNI 6592
Ø6 grower washer
UNI1751
M6 nut
UNI5588
OR6362
-
4.4
Comem OLI / Comem eOLI
Place the o-ring on the slot behind the gauge
(Fig.83/B) . Align the flange (Fig.18/C - stud length:
20±1 mm) with the threaded pins or holes (Fig.18/A)
(depending on the conservator flange type). The
gauge has to be assembled on the flange using four
screws M4x12 (Fig.18/D). The oil level indicator
flange has to be assembled using the items showed
in the table 5.
Q.ty
Description
4
Ø12 plane washer
4
Ø12 grower washer
4
M12 nut / screw
1
O-ring 6225
Table 5
B
Figure 18
Reference standard
UNI 6592
UNI1751
UNI5588
-
B
A
D
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comem eoliComem oli22Comem eoli22

Table of Contents