Fig. 10
Feka VS-VX
The Fekafos range is equipped with a 2" cast iron lowering device
and is therefore intended for use with one or two non automatic
single-phase pumps (Double models) or three-phase without float,
which must be installed in combination with a control panel.
A. Remove the tank cover.
B. FEKA VS-VX:
Check that the length of the pump float is 250 mm (see
fig 9a – pag.151).
Remove the top screw from the flange on the delivery
side (1).
Assemble the anti-rotation bracket (2).
Replace the screw (1).
Extract the slide from the coupling foot (5) and connect
it to the delivery port of the pump. Using the screw (6)
and the nut (4), fix the slide to the pump as indicated in
the figure 13.
C. GRINDER 1400-1800: Extract the slide from the coupling foot (5)
and connect it to the delivery port of the pump: using the screw
(6) M10X25
D. OTHER PUMPS (list in table page 27). Extract the slide (3)
from the coupling foot (5) and connect it to the delivery outlet by
means of the threaded flange supplied with the pump.
E. Reposition the slide/pump assembly on the foot (5).
2
3
PREPARED FOR THE FOLLOWING PUMPS
FEKA 600 MA
FEKA VS-VX 550 MA
FEKABOX 200
FEKA VS-VX 750 MA
FEKABOX 200 FX
FEKA VS-VX 1000 MA
FEKA VS-VX 1200 MA
FEKAFOS 280 l - FEKAFOS 280 l DOUBLE - FEKAFOS 550 l DOUBLE
Fig. 11 – Fig.12 – pag.152
ENGLISH
FEKABOX 200 l
FEKA FXV 20 MA
FEKA FXC 20 MA
DRENAG FX 15 MA
GRINDER FX 15 MA
Feka VS-VX
Fig. 13
26
3
2.1
5
Feka 600
4
2
1
5
3
6