Chapter 3. Software/Driver Installation
6. The installer will now search and display the drivers. Choose "Use" and hit [Enter].
7. The selected drivers will now be installed.
8. To install any additional drivers follow the same procedure mentioned above. Or choose
"Skip" and hit [Enter] to complete the driver installation.
3.2.

Runtime Installation

1. If you haven't done so already, download the Network driver (ISO image) from Chelsio
Download Center,
2. Copy the ISO image on to a host running XenServer.
3. Mount the image onto a directory by running the following commands:
[root@host~]# mkdir /tmp/iso
[root@host~]# mount -o loop <driver.iso> /tmp/iso
[root@host~]# cd /tmp/iso
install.sh
4. Run the
[root@host~]# ./install.sh
Chelsio T5/T4 Network Driver For XenServer
http://service.chelsio.com
script to install the drivers and tools
: