  • Page 1 version 1.7...
  • Page 2: Table Of Contents

    5.3.Interconnecting the ArcPower Micro 70 and the ArcLine Micro 36 ......5 5.4.DMX operation ......................6 5.5.Master-slave operation ....................7 6.ArcPower Micro 270 - Control menu map ..............8 7.ArcPower Micro 270 - DMX protocol ................9 8.Control board ......................... 10 8.1 Addressing the ArcPower Micro 70 ...............
  • Page 3: Safety Instructions

    CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
  • Page 4: Description Of The Arcpower Micro 270

    3.Description of the ArcPower Micro 270 1 - Display 5 - DMX input 2 - Control buttons 6 - DMX output 3 - Fuse Holder 7 - LED Module input 4 - Power cord DMX Input,Output RJ45 socket Front view of the socket:...
  • Page 5: Installing Instructions

    5.1.Mounting the ArcPower Micro 270 The ArcPower Micro 270 should be be placed on a non-f lammable f lat surface in any orientation and fixed by the  screws.There are 6 mounting holes of 5x7 mm in housing of the driver.
  • Page 6: Dmx Operation

    The ArcLine Micro 36 module consists of four 100mm-long stripes (with 9 LEDs each). Maximum number of connected ArcLine Micro 36 modules to the ArcPower Micro 270 is 7 (30 stripes maximum). The data/power cable with a standard length of 1m (2 pieces) for connection to the ArcLine Micro 360 is a part of delivery.If you need a longer cable,use five-core cable 5x 1.35 mm...
  • Page 7 Multiple ArcPower Micro 270 installation: Connect the DMX output of the first ArcPower Micro 270 with the DMX input of the next ArcPower Micro 270. Always connect one output with the input of the next ArcPower Micro 270 until all fixtures are connected.In this way,up to 32 fixtures can be chained together.
  • Page 8: Master-Slave Operation

    5.5.Master-slave operation 1.Unplug from the mains before installation. 2.Connect the LED stripes to the fixtures. 3.Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected.Up to 32 fixtures can be connected in master/slave chain 4.Insert the termination plug (with 120 Ohm) into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link.
  • Page 9: Arcpower Micro 270 - Control Menu Map

    6.ArcPower Micro 270 - Control menu map Default settings=Bold print 001 (001-507) E.P.1 E.P. E.P.3 P.01 P.10 Aut (OFF,On) EdI. E.P.1 E.P. E.P.3 S.01 S.50 rEd (0-255) diM. (0-255) FA.t.(0-255) S.tI. (0-255) COP. MAn. rEd (0-255) (0-255) (0-255) (0-255) MAC. (0-255) Str.
  • Page 10: Arcpower Micro 270 - Dmx Protocol

    7.ArcPower Micro 270 - DMX protocol version 2.0 (software version 1.3 and higher) Mode/ Type Channel Value Function of control RED LED 0-55 Red LED saturation control (0-100%) proportional GREEN LED 0-55 Green LED saturation control (0-100%) proportional BLUE LED...
  • Page 11: Control Board

    Use [UP],[DOWN] to browse through the menu.In order to to select a function or submenu,press [ENTER]. 8.1 Addressing the ArcPower Micro 270 The fixture can be operated in the two modes:DMX mode-fixture is controlled via DMX 512 by an external...
  • Page 12: Manual Mode

    Programming procedure: 1. Enter "EdI." menu . Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER]. 3. Press [UP] or [DOWN] to select the desired program step ("S.01" - "S.50") and press [ENTER]. 4.
  • Page 13: Test Sequences

    For detail description of all channels see DMX protocol. i.bL. --- Initial blink.If this function is on,ArcPower Micro 270 makes auto-calibration (All LEDs light on 100% for short time) after switching it on.If this function is set off,you have to set manually every colour on max.brightness after switching on the driver before starting regular operating.This action should last min.
  • Page 14 To update software in the fixture: 1.Installation of DMX Software Uploader: 1.DMX Software Uploader program is available from the ANOLIS web site at WWW.anolis.cz. 2.Make a new directory ( e.g. ANOLIS_Uploader) on your hard disk and download the software to it.
  • Page 15: Technical Specifications

    9.Technical Specifications: Power supply: Input Voltage:100-40V AC, 50/60 Hz Fuse:T 1.5A H Max.Pover Consumption:60VA Input: Control:DMX 51 DMX connection: RJ 45 Output: Max.Output Voltage:1V DC Total output power: 50.4Watts Max.load: 7 modules of ArcLine Micro 36 (30 stripes-270 LEDs)* *The ArcLine Micro 36 module consists of four 9-LEDs stripes DMX channels: Channel Mode 1...
  • Page 16: Replacing The Fuse

    10. Replacing the fuse 1.Before replacing the fuse, unplug mains lead! 2.Unscrew the fuse holder on the rear side of the ArcPower Micro 270 with a fitting screwdriver from the hous- ing (anti-clockwise). 3.Remove the old fuse from the fuse holder.