CAUTION! Unplug mains lead before opening the housing! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START - UP! 1. Safety instructions Every person involved with installation and maintenance of this product has to: - be qualilfied - follow the instructions of this manual CAUTION! Be careful with your operations.
5.1.Mounting the ArcPower Micro 270 The ArcPower Micro 270 should be be placed on a non-f lammable f lat surface in any orientation and fixed by the screws.There are 6 mounting holes of 5x7 mm in housing of the driver.
The ArcLine Micro 36 module consists of four 100mm-long stripes (with 9 LEDs each). Maximum number of connected ArcLine Micro 36 modules to the ArcPower Micro 270 is 7 (30 stripes maximum). The data/power cable with a standard length of 1m (2 pieces) for connection to the ArcLine Micro 360 is a part of delivery.If you need a longer cable,use five-core cable 5x 1.35 mm...
Page 7
Multiple ArcPower Micro 270 installation: Connect the DMX output of the first ArcPower Micro 270 with the DMX input of the next ArcPower Micro 270. Always connect one output with the input of the next ArcPower Micro 270 until all fixtures are connected.In this way,up to 32 fixtures can be chained together.
5.5.Master-slave operation 1.Unplug from the mains before installation. 2.Connect the LED stripes to the fixtures. 3.Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected.Up to 32 fixtures can be connected in master/slave chain 4.Insert the termination plug (with 120 Ohm) into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link.
7.ArcPower Micro 270 - DMX protocol version 2.0 (software version 1.3 and higher) Mode/ Type Channel Value Function of control RED LED 0-55 Red LED saturation control (0-100%) proportional GREEN LED 0-55 Green LED saturation control (0-100%) proportional BLUE LED...
Use [UP],[DOWN] to browse through the menu.In order to to select a function or submenu,press [ENTER]. 8.1 Addressing the ArcPower Micro 270 The fixture can be operated in the two modes:DMX mode-fixture is controlled via DMX 512 by an external...
Programming procedure: 1. Enter "EdI." menu . Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER]. 3. Press [UP] or [DOWN] to select the desired program step ("S.01" - "S.50") and press [ENTER]. 4.
For detail description of all channels see DMX protocol. i.bL. --- Initial blink.If this function is on,ArcPower Micro 270 makes auto-calibration (All LEDs light on 100% for short time) after switching it on.If this function is set off,you have to set manually every colour on max.brightness after switching on the driver before starting regular operating.This action should last min.
Page 14
To update software in the fixture: 1.Installation of DMX Software Uploader: 1.DMX Software Uploader program is available from the ANOLIS web site at WWW.anolis.cz. 2.Make a new directory ( e.g. ANOLIS_Uploader) on your hard disk and download the software to it.
10. Replacing the fuse 1.Before replacing the fuse, unplug mains lead! 2.Unscrew the fuse holder on the rear side of the ArcPower Micro 270 with a fitting screwdriver from the hous- ing (anti-clockwise). 3.Remove the old fuse from the fuse holder.
Need help?
Do you have a question about the ArcPower Micro 270 and is the answer not in the manual?
Questions and answers