VENTAIR EASY DUCT
Model: 10380 & 10383
The IXL Ventair Easy Duct has been designed to exacting standards to give you many years of trouble free operation. To ensure you get the most from your Ventair there are a few simple points to keep in mind.
VENTILATION
To ensure optimum performance of the exhaust fan, it is essential that there is adequate air flow into the room
to help the Ventair's powerful and efficient ducted fan to quickly remove steam and fumes. Ensure adequate
inlets exist through windows, vents or under the door. Air flow path from inlet to fan should ideally pass over
the steam or cooking fume source .
If the inline exhaust is used in a room where there is any fuel burning appliances, such as a stove or fireplace,
please ensure there is adequate ventilation to ensure the entry of clean air into the room and prevent the
backflow of exhaust gases.
CLEARANCE
The Ventair Inline exhaust is designed to fit a ceiling cavity or betwenn floor space with a minimum height of
230mm.
INSTALLATION
A switched power outlet/ supply is required for the Ventair Inline Exhaust - model 10380 & 10383 (Aust and NZ). This switched
!
power supply must be in accordance with AS/NZS 3000 (Wiring Rules) or equivalent for your particular area.
For installations in the Eire and UK markets this product should be wired to a suitable terminal block as per local wiring rules.
!
Ensure that Class II rating is maintained
Locate where the inlet and outlet grilles are to be located. Ensure that there is a clear path for the 150 mm diameter flexible
!
ducting to the grille positions.
Cut 160mm holes for the inlet and outlet grilles.
!
Fit the inlet grille base into the ceiling.
!
Fit backdraft flaps to Ventair blower, ENSURE FLAPS ARE MOUNTED AT BLOWER OUTLET.
!
Locate the blower unit at the highest position in the ducting system. The blower unit may be fixed by means of suitable fasteners
!
such as screws to a support straddling two ceiling joists suitably supported by vibration isolating material such as soft rubber
matting or an insulation batt, or by suspending it from the roof rafters with straps. See figures 1, 2.
Ensure that the Ventair blower is orientated in the correct direction. Refer to arrow on side of unit.
!
Measure the length of ducting between the grilles to the blower unit and cut the ducting to length.
!
WHEN INSTALLED THE DUCTING SHOULD BE STRETCHED STRAIGHT. Do not use longer ducting than necessary as excess length
!
will reduce the airflow delivery. Ensure ducting at outlet of blower does not interfere with backdraft flaps
Tape the ducting to the inlet and outlet grilles. If the outlet grille is located in the eaves it may be necessary to pass the ducting
!
out through the hole, tape it to the grille base and then fit the grille base in the hole.
Fit grille louvres to the grille bases.
!
This appliance must be mounted with the lowest point at least 2.1m from the floor.
!
TO ENABLE SERVICE, ACCESS TO THE INLINE BLOWER MUST BE PROVIDED.
!
SAFETY NOTES
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
!
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure they do not play with the appliance.
!
This product complies with EU Directives 2002/96/EC and 2002/95/EC.
The crossed-out dust bin symbol reported on the appliance indicates that the appliance must be disposed of separately from other domestic refuse at the end of its useful life. It must
therefore be delivered to a waste recycling centre specifically for electric and electronic equipment or returned to the retailer at the moment of purchase of a new equivalent
appliance.
The user is responsible for delivering the appliance to the appropriate collection centre at the end of its useful life. Failure to do so may result in a fine, as provided by laws governing
waste disposal. Differential collection of waste products for eventual recycling, treatment and environment and health, and also enables the materials making up the product to be
recycled.
For more detailed information on the available refuse collection systems, refer to the local Municipal Solid Waste disposal centre or the shop where the product was purchased.
Producers and importers are responsible for fulfilling their obligations as regards to recycling, treatment and environmentally friendly disposal by direct or indirect participating in
the collection system.
Specifications: Supply Voltage 230 - 240 V ac
Straps from rafters
Fig. 1
4 x fixing hole in outer masonry wall
Ø 160 mm hole
Impellor: 175mm dia. Duct diameter: 150mm
Installation Instructions
Screws
Fig 2.
Vibration Isolating Material
Wiring - Aust & NZ
ISOLATING SWITCH
A
N
E
EARTH
Wiring - UK & Eire
ISOLATING
SWITCH*
BROWN
Fig. 3
A
BLUE
N
MODEL
10380
10383
215mm
215mm
HEIGHT
LENGTH
272mm
254mm
RATING
40 W
75 W
55 l/s
96 l/s
AIRFLOW