2-1. Cleaning of Air Filter

Clean the filter at the inside of the front panel periodically
because it apt to catch dust.
It is recommended to replace the filter every five years as a
guide.
. Filter (3U) : 2-139-072-03
c
If the BDX-M1000 is kept on operating with too dusty of
the filter, the temperature inside the unit getting rise. This
may cause a fire.
Procedures
1. Turn the power off.
2. Loosen the locking screw on the front panel using a
flatblade screwdriver.
3. Pull the locking screw toward you and open the front
panel.
Front panel
4. Peel the filter away from the tapes.
Front panel
Tape
Tape
Filter
BDX-M1000
Section 2

Service Overview

Locking screw
5. Clean the dust on the filter using a vacuum cleaner.
n
If the filter is too much dusty, it is recommended to
wash it.
When washing the filter, be sure to dry it well.
6. After cleaning, fasten the filter to the tapes.