Mounting and Connection Instructions - Door module RS485
5.
Now the peripheral devices can be connected. Observe the connection diagrams and the terminal
assignments!
Then mount the housing cover, close it with the housing screws and seal it.
To assure safe and easy working, we recommend removing the holder with integrated tamper
switch during the installation of the peripheral devices.
5.
Technical data
5.1
Technical data 026593.10, Door module 12V DC, RS485
Rated operating voltage
Operating voltage range
Current consumption in no-load operation
without ext. consumers
Operating temperature range
Storage temperature range
Environmental class according to VdS
Color of the plastic housing
Dimensions (W x H x D)
5.2
Technical data 026594.10, Door module 230V AC, RS485
The performance features are the same
as for Item no. 026593.10
Battery support:
In addition:
Rated operating voltage
Operating voltage range
Current consumption in no-load operation
without ext. consumers
Operating temperature range
Storage temperature range
Environmental class according to VdS
Color of the plastic housing
Bottom of the housing
Dimensions (W x H x D)
12V DC
9V DC to 15V DC
15 mA
-5 °C to +55 °C
-25 °C to +70 °C
II
grey-white (similar to RAL 9002)
163 x 152 x 40 mm
1 x 018002 (2,0 Ah)
Power supply unit with
battery charging connection
230 V AC
230 V AC - 15% to + 10%
65 mA
-5 °C to +55 °C
-25 °C to +70 °C
II
grey-white (similar to RAL 9002)
2 mm steel sheet
250 x 210 x 100 mm
15