Mounting Guidelines - Honeywell Accentic proX2 Mounting And Operating Instructions

Reader with keypad, rs-485 and clock/data interface, wiegand interface
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Operating Instructions - proX2-reader "Accentic" with keypad
4.2

Mounting guidelines

The reader is suitable for indoor and outdoor use. Mount directly on the wall or use a "standard f.m.
socket". The electronic unit is inserted in the back of the housing and locked into position with the
housing front (replaceable).
For mounting surfaces of metal, the transmission range of the transponder may be lower
than that of non-metallic surfaces. In this case, we urgently recommend adjusting the
range (see 6.4).
In order to operate and read the keypad optimally, install the reader at a
above the floor.
When used outdoors, do not expose the reader to the weather.
If necessary, use the plastic shield (weather/view) Item no. 023501.
To mount, lift the housing front at the bottom and unhook at the top. When installing the housing back,
remove the electronics to avoid damage.
The housing back has two 60 mm boreholes for wall and f.m. sockets. To fix securely, use screws that
are suitable for the mounting surface in question.
-
In masonry with S6 plug:
-
In wood, depending on type: Semi-circular wood screw with slot 3.5 x 45 to 3.5 x 60 mm
-
In metal:
-
On the standard s.m. socket Semi-circular wood screw with slot 3.0 x 40 mm and washer
For additional fixing, the third borehole can be used (see 4.1). Choose the correct screw length for
the mounting surface.
When mounting, feed the connecting cable, if possible, from the back through an empty pipe
allowing sufficient spare cable.
Attention!
If the reader is to be used outdoors,
the cable bushing must be sealed
both sides
of the wall, (e.g. with
plaster
)
to prevent condensation
from forming!
When mounting on an f.m. socket or
on a cavity wall, install the socket so
that the fixing holes are horizontal
(see illustration).
To
lock the housing
seals at the bottom. The housing cannot be opened
without destroying the seal.
E.g. semi-circular wood screw with slot 3.5 x 60 mm
Fillister head screw M3 x 30 mm (min.) with washer
on
press in one of the enclosed
Fixing holes
60 mm
Observe notches
height of 130 to 140 cm
21

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

026421.10026421.20

Table of Contents