Wiegand Interface; Start-Up; Operation With Transponders; Allocate Addresses - Honeywell Accentic proX2 Mounting And Operating Instructions

Reader with keypad, rs-485 and clock/data interface, wiegand interface
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Operating Instructions - proX2-reader "Accentic" with keypad
5.3

Wiegand interface

F
i
3
1
2
4
5
6
7
8
9
3
r
0
026421.20
6.

Start-up

6.1

Operation with transponders

Hold the transponder approximately
In order to achieve a greater transmission range when using the transponder, a relatively high
current is required during transmission (<50 mA).
Without transponder transmission (5 sec. after the last transmission), the
switches from active mode to low current mode and thus reduces the current consumption on
average to <11 mA.
If the transponder is used in conjunction with a reader in low current mode, it may take
up to 1.2 sec. until it starts operating. Evaluation takes place within 0.9 sec. when the
read mode is activated.
6.2

Allocate addresses

6.2.1

Introduction

Every reader operated at an AC module bus must have its
the AC system prevents addresses from being allocated several times.
Possible
address range:
With the ACS-8 from V06.xx upwards, addresses can be allocated in different ways. The following
information is intended to assist you in choosing the best methods for your special requirement. A
detailed description on the individual methods can be found in the following chapters.
With the ACS-8, V05.xx, only the method described under 4.) is possible.
1.) Manually via the central control unit
Enter the unique number (serial number) of the reader plus the desired address via the
programming of the central control unit. The address is then stored in the reader.
Recommended standard methods.
2.) Automatically with transponder
Start the process with a transponder in the reading area of the reader. The address is
allocated automatically and then stored in the reader. As long as the address allocation
mode is active, several readers can be automatically allocated addresses in succession.
Recommendation:
Suitable for shorter distances between the AC central control unit and the individual
readers. (Manual input of the unique numbers of the readers is not required).
3.) Manually via reader keypad
An address is allocated via the keypad at the reader.
Recommended:
When a specific address has to be allocated to an reader on site.
4.) Manuelly via reader keypad - stand alone operating mode
Only
the reader voltage requires connecting at the reader. The address allocation mode
must not be active, neither is a connection to the ACS-8 necessary.
An address is allocated via the keypad at the reader.
Recommended:
When servicing or testing.
ATTENTION
in the middle of the keypad
1 to 32 (address 0 not applicable)
(see 6.2.5)
(see 6.2.6)
: A plausibility check is not possible!
red
blue
grey
red/blue
green
Shield
own
(see 6.2.4)
+U_b 12 V DC
0 V
D1
D0
LED green
.
reader
automatically
address. A
plausibility check
(see 6.2.7)
23
in