Rittal Micro Data Center Level E Operating Instructions Manual
Rittal Micro Data Center Level E Operating Instructions Manual

Rittal Micro Data Center Level E Operating Instructions Manual

Hide thumbs Also See for Micro Data Center Level E:

Advertisement

Quick Links

Micro Data Center Level E
7999.009
Operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Micro Data Center Level E and is the answer not in the manual?

Questions and answers

Summary of Contents for Rittal Micro Data Center Level E

  • Page 1 Micro Data Center Level E 7999.009 Operating instructions...
  • Page 2 Rittal GmbH & Co. KG Auf dem Stützelberg 35745 Herborn Germany Tel.: +49(0)2772 505-0 Fax: +49(0)2772 505-2319 E-mail: info@rittal.de www.rittal.com www.rittal.de We are always happy to answer any technical questions regarding our entire range of products. Rittal Micro Data Center Level E...
  • Page 3: Table Of Contents

    Disposal ............28 Technical specifications ....29 Accessories ........30 11.1 TS-IT server enclosure accessories ..... 31 Appendixes ........34 12.1 Cooling the Micro Data Center ....34 Warranty ........35 Customer service addresses ..36 Rittal Micro Data Center Level E...
  • Page 4: Notes On Documentation

    1 Notes on documentation Notes on documentation Manufacturer's statement Rittal GmbH & Co. KG confirms that the applicable safe- ty standards for the Micro Data Center Level E are ob- served. Storing the documents The operating instructions as well as all applicable doc- uments are integral components of the product.
  • Page 5: Safety Instructions

    2 Safety instructions Safety instructions Explosion hazard The Micro Data Center Level E produced by Rittal If UPSs with integrated or separate bat- GmbH & Co. KG is developed and produced with due tery packs are installed in the Micro Data regard to all safety precautions.
  • Page 6: Safety Notes For The Prevention Of Damage To The Micro Data Center

    – Any mains power connection or mains power wiring on the rating plate of the cooling system. required as part of the Micro Data Center Level E wir- The ambient temperature at the installation ing may only be performed by an experienced electri- site of the Micro Data Center must lie within cian.
  • Page 7: Operating And Technical Staff

    RoHS compliance The unit fulfills the requirements of EU directive 2011/65/EU on the Restriction of Use of Certain Hazard- ous Substances in Electrical and Electronic Equipment (RoHS 2) of June 08, 2011. Rittal Micro Data Center Level E...
  • Page 8: Product Description

    Product Description Components of the Micro Data Center Functional description The Rittal Micro Data Center Level E is a modularly ex- tendible IT security safe. It provides physical safety and protects against fire, water, acrid gases and unauthor- ised access.
  • Page 9: Standard System Components

    When steel tubes are inserted, an additional cable duct protection box must be placed in front of the soft duct. Rittal GmbH & Co. KG is not responsible for any damage which may result from failure to comply with the docu- Cable box mentation provided.
  • Page 10: Dimensions And Clearances

    – Use of impermissible tools. – Improper operation. – Improper rectification of malfunctions. – Use of accessories not approved by Rittal GmbH & Co. KG. Dimensions and clearances Information about the dimensions can be found on the dimensioned drawings in the Appendix.
  • Page 11: Assembly And Siting

    The items listed below are the standard requirements the opening and closing of the existing intermediate placed on the siting of the Micro Data Center Level E and floors and floors. must be satisfied by the customer.
  • Page 12 [2] and per- line b.) can be accepted by the floor construction di- mitted uniformly distributed characteristic live loads of rectly below the Micro Data Center surface.  5.0 kN/m². Rittal Micro Data Center Level E...
  • Page 13: Average Surface Load Of The Micro Data Center Level E

    The calculation of the average surface load line b.) ap- plies only to the surface directly under the Micro Data Center Level E. Rittal Micro Data Center Level E, 47 U, 1000 mm interior depth with two single-leaf doors Average surface load assuming a total weight of Components...
  • Page 14 4 Assembly and siting Rittal Micro Data Center Level E, 47 U, 1200 mm interior depth with two single-leaf doors Average surface load assuming a total weight of Components Weight [kg] 1340 kg (based on one Micro Data Center) Mico Data Center Level E Line a.) 437 kg/m²...
  • Page 15: Transport

    5 Transport Transport Note: The Micro Data Center may be transported only by trained specialists certified by Rittal GmbH & Co. KG. Rittal Micro Data Center Level E...
  • Page 16: Installation And Commissioning

    Installation and commissioning Components of the Micro Data Center Note: Note: The Rittal Micro Data Center is designed only The Micro Data Center may be installed and for use with officially approved units. commissioned only by trained specialists The safety of the configuration must be certified by Rittal GmbH &...
  • Page 17: Operation

    (not without delay. even an emergency key)! The interior of the Micro Data Center must not be entered! The safety doors do not have any panic unlocking on the inside. Rittal Micro Data Center Level E...
  • Page 18: Code-Combi B Electronic Key Combination Lock

    Code inputs can be cancelled by pressing the P key. The factory code setting for the lock is 123456. For safe- ty reasons, change this factory code setting immediately to your own personal code. Rittal Micro Data Center Level E...
  • Page 19 Parallel mode is the factory set- Programming tasks should be performed ting. only with opened lock and opened operator The 1 2 3 4 5 6 factory code is programmed as primary door! code. Fig. 4: Parallel mode Rittal Micro Data Center Level E...
  • Page 20 Enter the valid 6-digit primary code. the repeated input, the following signal message ap- signal message appears. pears three times  Press the P key.  Press the 0 key.  Repeat the action. signal message appears once. Rittal Micro Data Center Level E...
  • Page 21 If the lock was last opened with the dual code, the fol- lowing signal message occurs three times  Repeat the action. Rittal Micro Data Center Level E...
  • Page 22 2, 4, 8 and maximum 16 minutes. During the penalty time, the red LED flashes in second intervals and no further code input is possible. The penalty time can be overridden with the inspection key (see page 24). Rittal Micro Data Center Level E...
  • Page 23 (see page 24).  Turn the bar handle within 4 seconds clockwise until it reaches the limit. Deleting the programmed TD/OW  Open the lock with the valid code.  Press the ON key. Rittal Micro Data Center Level E...
  • Page 24  Press the 0 key.  Remove the empty battery and place the new battery signal message appears once. in the drawer.  Press the ON key. Rittal Micro Data Center Level E...
  • Page 25: Electronic Lock For Activation By An Access Control System

    Micro Data Center door. The cable for the connection to the system is made available inside the Micro Data Center. The power supply for releasing the Rittal Micro Data Center Level E...
  • Page 26 7 = positive trigger voltage See above See above 8 = negative trigger voltage Input unit Not assigned Pin1 of the respective socket Fig. 10: Interfaces Fig. 11: Pin assignment White Brown Green Yellow Grey Pink Blue Rittal Micro Data Center Level E...
  • Page 27: Inspection And Maintenance

    These safety inspections guar- antee the full operability of the Micro Data Center Level E. For questions concerning service and maintenance con- tracts, please contact our service operation: Tel.: +49(0)2772 505-1717 Rittal Micro Data Center Level E...
  • Page 28: Storage And Disposal

    9 Storage and disposal Storage and disposal Storage If the device is not used for a long period, Rittal recom- mends that it is disconnected from the mains power supply and protected from dampness and dust. Disposal The materials of the Micro Data Center should be han- dled as household refuse.
  • Page 29: Technical Specifications

    1000 1200 1200 Model No. (the Micro Data Center is configured on 7999.009 7999.009 7999.009 7999.009 7999.009 a project-specific basis) Empty weight excluding cooling unit and excluding rack approx. [kg] Tab. 1: Technical specifications Rittal Micro Data Center Level E...
  • Page 30: Accessories

    Busbars Component Model No. Remarks PSM Plus busbars 7856.015 Further vari- ants, refer to the cat- alogue PDU Power Distribution 7955.201 Further vari- Unit ants, refer to the cat- alogue Rittal Micro Data Center Level E...
  • Page 31: Ts-It Server Enclosure Accessories

    F [N ] Packs of X mm Packs of F [N ] Référence Référence UE (p.) UE (p.) TS DK – 5501.400 400 - 600 5501.460 5501.410 600 - 900 1500 5501.480 5501.420 5501.430 5501.440 5501.450 Rittal Micro Data Center Level E...
  • Page 32 11 Accessories Catalogue Best.-Nr. VE (St.) Model No. Packs of Référence UE (p.) 5502.115 Catalogue Best.-Nr. VE (St.) Model No. H mm HE/U/U Packs of Référence UE (p.) 2000 5502.105 2200 5502.145 Rittal Micro Data Center Level E...
  • Page 33 UE (p.) 2000 – 2200 5502.120 Catalogue Best.-Nr. VE (St.) Model No. Packs of Référence UE (p.) 5502.155 Catalogue Best.-Nr. VE (St.) Model No. Packs of Référence UE (p.) 7856.029 1 Satz/1 set/1 jeu Rittal Micro Data Center Level E...
  • Page 34: Appendixes

    The siphon installed in the drainage system must be filled with water so that an ingress of flue gases via the con- densate discharge is prevented. Rittal Micro Data Center Level E...
  • Page 35: Warranty

    Mi- cro Data Center, the validity of the recogni- tion of the test ratings is voided. In such cases, please contact the manufacturer with- out delay otherwise the warranty is voided. Rittal Micro Data Center Level E...
  • Page 36: Customer Service Addresses

    14 Customer service addresses Customer service addresses For technical questions, please contact: Tel.: +49(0)2772 505-9052 E-mail: info@rittal.de Homepage: www.rittal.com For complaints or service requests, please contact: Tel.: +49(0)2772 505-1855 E-mail: service@rittal.de Rittal Micro Data Center Level E...