Download Print this page

Sealey SA951015 Instructions page 2

Direct drive oil free compressors

Advertisement

DO NOT attempt to move the compressor by pulling the air tool’s hose. Only move the compressor by its handle.
7
DO NOT use this product to perform a task for which it has not been designed.
7
7
DO NOT deface the certification plate attached to the tank.
7
7
DO NOT cover the compressor or restrict air flow around the machine whilst operating.
7
7
DANGER! DO NOT direct the output jet of air towards people or animals.
7
s
DO NOT allow anyone to operate the compressor unless they have received full instructions.
s
7
p WARNING! The air tank is a pressure vessel and the following safety measures apply:
7
DO NOT tamper with the safety valve.
7
DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.
7
7
DO NOT subject the tank to impacts, vibration or to heat.
7
7
DO NOT allow contact with abrasives or corrosives.
7
7
DO drain condensation from tank daily and inspect inside walls for corrosion every 12 months. The tank shell must not fall
7
4
below the certified thickness at any point.
4
WARNING! If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.
p
When not in use, store the compressor carefully in a safe, dry, childproof location.
p
2.
INTRODUCTION & SPECIFICATIONS
Ideal for use where an oil-free air delivery is required and especially suited to small low pressure, touch-up and airbrush spraying applications
as well as general-purpose applications. Simple construction with fewer components makes these units practically maintenance-free. Reduced
weight gives greater portability and compressor can be transported and even operated on its side. All models are supplied with a precision
welded receiver tank, manufactured to meet Pressure Vessel Directive 87/404/EEC, fully automatic pressure cut-out switch and air regulator
with gauge. All have a handle and wheels and ASTA/BS approved non-rewirable plug.
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SA951015
Motor Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp
Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph
Input Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SA952515
Motor Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp
Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph
Input Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SA955015
Motor Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp
Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph
Input Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A
3.
PREPARATION
3.1
Remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged contact your supplier.
3.2
Save the packing material for future transportation of the compressor. We recommend that you store the packing in a safe location, at
least for the period of the guarantee. Then, if necessary, it will be easier to send the compressor to the service centre.
3.3
Confirm that the mains voltage supply corresponds with the voltage shown on the compressor data plate.
3.4
The compressor should be operated in a position that allows good air circulation around the unit.
Air Displacement: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm
Max. Free Air Delivery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm
Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10ltr
Max. Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar
Air Displacement: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm
Max. Free Air Delivery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm
Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25ltr
Max. Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar
Air Displacement: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm
Max. Free Air Delivery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm
Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50ltr
Max. Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar
Model No. SA955015
SA951015, SA952515 & SA955015 - 1 - 310105

Advertisement

loading

This manual is also suitable for:

Sa952515Sa955015