10. TROUBLESHOOTING ................11 1. GENERAL INFORMATION The electromechanical shaft operator Shaft-120 was designed for automation of industrial sectional doors. It consists of a mechanical reducer in “oil bath” and an electric motor with an integral control unit. The reducer and the motor have a common housing.
Save these instructions. Follow all instructions since incorrect installation can lead to severe injury. Shaft-120 was designed for automation of industrial sectional doors. Do not use the operator for other than intended purposes. DoorHan shall not be held responsible in case of injury caused by misuse of the product.
Page 4
Do not use the operator if it needs repair or adjustment as installation defects or unbalanced door can cause injury. DoorHan shall not be held liable in case of improper installation of the item and damage arisen during operation. ...
OPERATOR UNIT 3. OPERATOR UNIT Release cord Motor Manual chain Control unit Reducer housing Manual drive unit Limit switches 4. OPERATOR INSTALLATION 4.1. TOOLS Set of spanners Set of drills for concrete Electric drill Set of slotted and cross screwdrivers Pliers Tape measure (folding rule) Set of drills for metal...
ELECTRICAL CONNECTIONS Install the operator on the Closing ring Bushing key Electric operator Closing ring Fastening bracket Shaft door shaft (make sure, that the bushing key is in proper position) and screw it to the mounting basis. Install the second closing ring ...
ELECTRICAL CONNECTIONS 5.1. CONTROL BLOCK WIRING DIAGRAM Motor 380 V Supply voltage Supply selection jumper Fuse voltage 3×380 V 50 Hz Transformer DIPs Дипы Close Stop button Open button button WARNING! If there are Внимание! no safety devices, install Limit switches При...
Page 8
ELECTRICAL CONNECTIONS 3. Motor (terminal block X4) Connect the motor to terminals “U”, “V” and “W”. 380V motor: max. operating current < 9 A, wattage ≤ 4 kW. 3~Motor: 380 V 4. Limit switches (terminal block X0) Connect limit switch wires “OP” (opening switch), “CL” (closing switch) and “GND” (common wire). Close Open Common 5.
ADJUSTMENT OF EXTREME POSITIONS 6. ADJUSTMENT OF EXTREME POSITIONS 6.1. CLOSE POSITION (RED CAM) Coarse adjustment Make sure, that the operator is fixed rigidly; put the door in completely closed position. Loosen the screws for coarse adjustment of red cams, then turn them so, that the microswitches are pushed, then tighten ...
8. RELEASE OPERATION The electric operator Shaft-120 is equipped with a manual chain reducer, which is used for emergency lifting/lowering of the door in case of a power cut. For emergency control, pull the cord with a red handle down up to the stop to prevent automatic actuation of the operator.
The Shaft-120 automatic system does not require any special servicing. Repairs may be carried out only by a qualified technician trained and certified at an authorized DoorHan centre. Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency ...
Page 12
We very much appreciate that you have chosen the product manufactured by our company and believe that you will be satisfied with its quality. For information on purchasing, distribution and servicing contact DoorHan central office at: Kralovsky VRCH 2018, Kadan, 43201, Czech Republic Telephone: +420 474 319 111 E-mail: europe@doorhan.com...
Need help?
Do you have a question about the SHAFT-120 and is the answer not in the manual?