II - Installation of the products
2.1 Recommendations before installation
The location where the sounder is to be installed must be chosen according to the presence of
PoE+ network cable nearby (depending on the version of the product, the cable is fed through the
back ot the product or through its top, so plan accordingly).
The identification of one or more Harmonys sounders, requires the presence of one or two
persons:
- 1 person: we recommend wiring Harmonys one by one to your bay. You can then locate the
sounder easily as long as the cable is identified.
The identification (finding the MAC address) can also be simply done by pressing the test button
of the Harmonys Trio .
- 2 persons: a person making the identification from software (see manual 607726). The
second person standing in the area where the Harmonys sounder is located to hear beeping in
order to identify it (eg: hallway, foyer).

2.2 Wall sounder

1 / To open the sounder, unclip the front panel by manually pulling on the white plate. Note that the
sounder is shipped with the loudspeaker and the LED display disconnected.
Do not use tools to unclip the front panel as this may damage the product.
2 / Feed the Ethernet cable through the opening in the back panel and fix the sounder in place
using the 4 screws.
3/ Make sure that the wall sounder is flat against the wall.
4/ Connect the Ethernet network cable to the RJ45 connector. To make the
connection easier make a loop with the Ethernet cable inside the casing.
Ethernet cable category: 5 minimum or 6.
5/ Connect the loudspeaker in A and the flat cable of the LED display in B as shown below.
The broadcast mode will have to be selected in the Network configuration page (17) of the
embedded web server, in Multicast mode the address of the product must be the same than that
of the master clock (by default 239.192.55.1).
Pattern dimensions (in mm) for wall installation:
90
87,2
53,3
163,8
B
A
B
A
5