I N S TA L L AT I O N
Backlight
Indirect Sunlight
through Window
Close to Light
3
1&2
3. Align the device with the mounting plate and hang the device on the
mounting plate. Make sure the two sheets on each side of the mounting
plate have been in the slots at the back of the device.
4. Use 2 supplied screws (SC-M4×14.5TP10-SUS) to secure the device and
the mounting plate.
4
Direct Sunlight
Direct Sunlight
through Window
Installation Environment:
• The device should be at least 2
meters away from the light, and
at least 3 meters away from the
window.
• Make sure the environment illumi-
nation is more than 100 Lux.
• Indoor and windless environment
use only.
Steps:
1. Drill holes on the wall or other sur-
face and install the gang box.
2. C o n n e c t t h e t h er m o gr a p h i c
module and the main body of the
device. Use 5 supplied screws
(4_KA4×22-SUS) to secure the
mounting plate on the gang box.
4
4