6. Secure the back tamper unit directly to the wall (Fig. 6) or to the bracket screwed down to the
wall or ceiling (Fig. 7). If the pet immunity option is enabled, the detector cannot be mounted
on the bracket.
7. Fasten the enclosure base to the back tamper unit (Fig. 8).
8. Fasten the electronics board, taking into account the height of detector installation (Fig. 9).
9. Close and open the tamper contact that detects the cover removal to start the test mode, and
then close the detector enclosure.
10. Check that movement within the coverage area will make the LED light up.