Wireless passive infrared detector

Advertisement

SATEL
4. Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in accordance
with the existing rules for environment protection.
Do not touch the pyroelectric sensor, so as not to soil it.
1. Open the enclosure (Fig. 4).
2. Configure the detector by means of jumpers.
3. Install the battery and register the detector in the MICRA alarm module (see the manual for
MICRA alarm module).
4. Select the place of installation. Check that the transmissions from the detector placed at that
point reach the MICRA alarm module. In order to send a transmission, close and open
simultaneously both tamper contacts. If the alarm transmission is received, continue with the
installation. If the alarm transmission is not received, select a different mounting location and
repeat the test.
5. Remove the electronics board (Fig. 5).