Summary of Contents for Roto Safe

  • Page 1 Window and Door Technology Roto Safe cable junction Matching hardware technology everything about doors Installation, maintenance and operation instructions for timber, PVC and aluminium profiles...
  • Page 2 Contact Contact Roto Frank Fenster- und Türtechnologie GmbH Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen Germany Phone +49 711 7598 0 Fax +49 711 7598 253 info@roto-frank.com www.roto-frank.com 2 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 3: Table Of Contents

    2.3.4 Stipulated use........................15 2.3.4.1 Misuse..........................15 Operation..........................Information on the product................... Overview..........................Technical data........................Bush and connector......................19 Overview of variants......................Installation......................24 Processing instructions......................24 Dimensions........................... Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 3...
  • Page 4 10.2 Disposing of hardware......................43 10.3 Electronic waste........................43 Accessories......................11.1 Cable............................. 11.2 Retaining bracket........................11.3 Cover plate..........................11.4 Eneo power supply unit......................11.5 Eneo connector set....................... 4 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 5 Table of contents Additional information...................48 12.1 Declaration of Conformity.....................48 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 5...
  • Page 6: General Information

    Roto Safe Eneo C / CC / CF installation instructions: IMO_438 ■ Brief instructions ■ Roto Safe Eneo A / AF and Eneo C / CC / CF: SUG_11 Power supply unit specifications: SUG_3 Instructions and information relating to the individual hardware ■...
  • Page 7: Symbols

    Amperes Width Celsius approx. approximately Catalogue etc. et cetera Height Installation instructions Kilograms Metres Mat. no. Material number max. Maximum Millimetres Square millimetres Depth Volts Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 7...
  • Page 8: Explanation Of Terms

    End users The “end users” target group includes all individuals who use the installed doors. 8 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 9: Fabricator

    (e.g. VDE regulations, BGR guideline, DIN standards) to be able to evaluate whether cable junctions for doors are safe to operate. Adherence to the relevant local installation regulations and provisions is required for installation.
  • Page 10: Copyright Protection

    The warranty only covers original Roto components. We reserve the right to make technical changes as part of improvement to performance characteristics and further development.
  • Page 11 Discharge any humidity present in the room air to the outside using condensation dryers. Establish a ventilation plan for more complex construction projects if necessary. Provide adequate ventilation during holiday periods as well. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 11...
  • Page 12: Security

    This manual contains instructions relating to safety. The principal safety infor- mation in this chapter includes information and instructions relevant to the safe use or maintaining the safe condition of the product. Warning instruc- tions that relate to handling warn of residual risks and are located before steps that are relevant to safety.
  • Page 13: Installation

    Gripping between the sash and frame when closing windows and balcony doors poses the risk of crushing injuries. When closing windows and balcony doors, never grip between the sash and frame and always exercise caution. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 13...
  • Page 14: Ambient Conditions

    Windows and balcony doors, including the hardware, require expert mainte- nance (care, cleaning, maintenance and inspection) in order to guarantee their proper condition and safe use. Keep the hardware free of deposits and contaminants. Carry out care and cleaning tasks as specified in these instructions.
  • Page 15: Stipulated Use

    Note the product-related documentation  from page 2.4 Operation The safety symbols and markings and the associated warning instructions explained below apply to the safe operation of windows and balcony doors. Safety symbols and markings Symbol Meaning Falls from open windows and balcony doors present an immediate risk of death and pose the risk of serious injuries.
  • Page 16 Pressing the sash against the edge of an opening (reveal) may pose a risk of minor injuries and cause property damage Refrain from pressing the sash against the edge of an opening (reveal). 16 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 17: Information On The Product

    No ventilation slot required for timber ■ The join between the frame and leaf has IP67 ■ protection Scope of delivery 1x cable junction ■ Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 17...
  • Page 18: Technical Data

    IP67 (when inserted and only the plug connection between leaf and frame) Temperature range When idle: -10 °C to +70 °C When moving: -10 °C to +50 °C Standards CE conformity 18 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 19: Bush And Connector

    Bush and connector 3.3 Bush and connector Schematic diagram of bush Cable: LIF9Y11Y, 6 x 0.34 mm Schematic diagram of connector Cable: LIF9Y11Y, 6 x 0.34 mm Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 19...
  • Page 20: Overview Of Variants

    Variant 1 – rebate clearance 12 / 16 mm Mat. no. 820187 Mat. no. 820255 Installation situation [1] Frame component [2] Leaf component [3] Cover plate (  from page 20 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 21 Mat. no. 820194 Installation situation [1] Frame component [2] Leaf component [3] Retaining bracket (  from page  from page [4] Cover plate ( Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 21...
  • Page 22 Overview of variants Variant 3 – rebate clearance 12 / 16 mm Mat. no. 817028 Mat. no. 820255 Installation situation [1] Frame component [2] Leaf component 22 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 23 Variant 4 – rebate clearance 4 / 12 mm Mat. no. 817028 Mat. no. 820194 Installation situation [1] Frame component [2] Leaf component [3] Retaining bracket (  from page Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 23...
  • Page 24: Installation

    In addition to the generally applicable rules of good engineering practice, the following technical regulations must ■ be complied with, in particular: VDS 2311, VDE 0100. 4.2 Dimensions Frame components Frame side without power supply unit Ø 4.9 10.4 24 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 25 Installation Dimensions Frame side with power supply unit 19.4 Ø5 41.6 Sash components Sash side without casing (lengthways installation) 11.8 Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 25...
  • Page 26: Drilling And Routing Dimensions

    Only tighten screws by hand. Recommendation: predrill screw holes. Frame component without power supply unit + leaf component without casing [1] Routing depth: 30 mm 26 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 27 Frame component with power supply unit + leaf component without casing [1] Routing depth: 42 mm [2] Routing depth: 3 mm [3] Routing depth: 30 mm Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 27...
  • Page 28: Installation

    Lay a cable loop, ensuring that there is enough spare cable. INFO Do not crush or damage the cable when installing the frame. 3. Secure the mounting casing with screws [2]. 28 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 29 Installation Installation Leaf side Frame side Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 29...
  • Page 30 Chips in the connector or bush may cause a short-circuit. Keep the bush and connector clean. INFO Note the anti-twist protection of the plug connection. 30 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 31 Only an electrician may connect the power supply unit to the mains voltage. Observe and comply with the respective national regulations (in Germany VDE 0100 and others). Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 31...
  • Page 32: Connection Diagram

    Proper operation is the responsibility of the customer. The customer is obligated to ensure safe installation, use, maintenance and operation. The customer is furthermore obligated to ensure that the equipment is only installed by a qualified electrician; failure to do so may result in a risk of fire or risk of electric shock.
  • Page 33: Eneo A / Af With Phone & Code, Power Supply Unit In General

    OUT: Inside: 24 V DC The “Unlock door” push-button can be used as an option. 230 V AC Intercom Cable, 3 m Signal (e.g. 12 V) brown white potential-free contact Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 33...
  • Page 34: Eneo C / Cc / Cf With Phone & Code, Power Supply Unit In General

    White a relay and a 47 ohm resistor. Potential-free contact The maximum load of the contacts is 24 V / 40 mA 34 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 35: Operation

     LED is lit up green when there is voltage. 2. When the door is installed, test the electrical multipoint locking system and any access control systems that are fitted. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 35...
  • Page 36: Maintenance

    The manufacturer must draw the attention of builders and end consumers to these maintenance instruc- tions. Roto Frank Fenster- und Türtechnologie GmbH recommends the manufacturer conclude a maintenance agreement with their end users. No legal claims can be derived from the following recommendations; their application is to be based on the specific individual case.
  • Page 37: Maintenance Intervals

    Door lever handle function Push the door lever handle all the way down and release. The door lever handle must automatically return to the initial position. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 37...
  • Page 38 With the door locked, turn the key in the unlocking direction. The key must be easy to turn. The latch and all deadbolts must retract fully. 38 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 39: Repair

    7.4 Repair WARNING Improper repair work may pose a risk of death! Improper maintenance may prevent the element from working properly and make it less safe to use. Always have repairs performed by a specialist company. ATTENTION Improper screw fixings may cause property damage.
  • Page 40: Dismantling

    Use a hex key or suitable screwdriver to undo the plug connection. 4. Unhinge the sash. 5. Protect the plug connection against dust and moisture. 40 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 41: Transport

    Use the following transportation means for support when transporting, loading and unloading larger scopes of delivery: Industrial trucks, e.g. forklifts, telescopic handlers, pallet trucks ■ Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 41...
  • Page 42: Storing The Hardware

    Immediately check the delivery for completeness and transport damage on receipt. ATTENTION Strong vibration may cause property damage. Strong vibration can permanently damage the magnet and contact element. Avoid vibration during transport. 42 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 43: Disposal

    According to the Federal Electrical and Electronic Equipment Act (ElektroG) in Germany, waste electronic equipment must not be disposed of in household waste; it must be taken to an appropriate disposal site. Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 43...
  • Page 44: Accessories

    Can be used with cable extensions as clamping protection 1 piece 775949 Dimensions (W x H): 45 x 15 mm Recommended for doors with multiple rebates Improves the cable routing 44 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 45: Cover Plate

    Cover plate for PVC and aluminium for cable junction 820187 Fixing the cable junction on the frame with mount for retaining bracket 1 piece 817121 Stainless steel U6x24, length: 190 mm Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 45...
  • Page 46 Cover plate for PVC and aluminium for cable junction 820187 Fixing the cable junction on the frame 1 piece 619589 Stainless steel F3x16, length 126 mm 46 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 47: Eneo Power Supply Unit

    1 piece 796383 24 V, 2.5 A, HDR-60-24 11.5 Eneo connector set Eneo connector Eneo connector, 3-pin 1 piece 494801 2 pieces (green and black) Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 47...
  • Page 48 Additional information 12 Additional information 12.1 Declaration of Conformity 48 · 05 / 2020 · IMO_502_EN_v2 Roto Safe - Cable junctions Subject to change.
  • Page 49 Additional information Declaration of Conformity Subject to change. Roto Safe - Cable junctions IMO_502_EN_v2 · 05 / 2020 · 49...
  • Page 50 70771 Leinfelden-Echterdingen Germany Phone +49 (0) 711 7598 0 +49 (0) 711 7598 253 info @ roto-frank.com www.roto-frank.com From a single source: Optimum hardware systems to meet all challenges Roto Tilt&Turn The Tilt&Turn hardware system for windows and balcony doors...