8.19. Disassembly of Meter Illumi
LED L P.C.B. and Meter Illumi
LED R P.C.B.
• Refer to "Disassembly of Top Cabinet Ass'y".
• Refer to "Disassembly of Front Panel Unit".
• Refer to "Disassembly of Shade Sheet B".
Step 1 Remove 3 screws.
Step 2 Detach 6P Wire at the connector (P8901) on Meter
Illumi LED L P.C.B..
Step 3 Remove Meter Illumi LED L P.C.B. and Meter Illumi LED
R P.C.B..

8.20. Disassembly of Meter P.C.B.

• Refer to "Disassembly of Top Cabinet Ass'y".
• Refer to "Disassembly of Front Panel Unit".
• Refer to "Disassembly of Shade Sheet B".
Step 1 Detach 6P Cable at the connector (P8901) on Meter
Illumi LED L P.C.B..
Step 2 Remove 2 screws.
Step 3 Desolder the pins of Meter P.C.B..
Step 4 Remove Meter P.C.B..

8.21. Disassembly of Meter Unit

• Refer to "Disassembly of Top Cabinet Ass'y".
• Refer to "Disassembly of Front Panel Unit".
• Refer to "Disassembly of Shade Sheet B".
• Refer to "Disassembly of Meter Illumi LED L P.C.B. and
Meter Illumi LED R P.C.B.".
• Refer to "Disassembly of Meter P.C.B.".
Step 1 Remove 4 screws.
Step 2 Remove Shade Sheet A.
Step 3 Remove 4 screws.
Step 4 Remove Meter Unit.