IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contami-
nants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before
servicing the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation
such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS (b) User's manual (c) USB A+B type cable (d) Function Setup Guide
*PowerPanel® Personal software is available on our website. Please visit
Section for free download.
OVERVIEW
The LX1100G-FC/LX1325GU-FC/LX1500GU-FC provides complete power protection from utility power that is not always consistent. The
LX1100G-FC/LX1325GU-FC/LX1500GU-FC features 890 Joules of surge protection. The unit provides long lasting battery backup during
power outages with maintenance free batteries. The LX1100G-FC/LX1325GU-FC/LX1500GU-FC ensures consistent power to your computer
system and includes software that will automatically save your open files and shutdown your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The LX1100G-FC/LX1325GU-FC/LX1500GU-FC stabilizes inconsistent utility power voltage to nominal levels that
are safe for equipment. Inconsistent incoming utility power may be damaging to important data files and hard-
ware, but with Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels. AVR
automatically increases low utility power or decreases high utility power to a consistent and safe 110/120 volts.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1.
Ensure that the equipment plugged into the outlet does not exceed the UPS's rated capacity (1100VA/660W
for LX1100G-FC, 1325VA/810W for LX1325GU-FC, 1500VA/900W for LX1500GU-FC). If the rated capacity of the unit is exceeded, an
overload condition may occur and cause the UPS to shut down or the circuit breaker to trip.
2.
There are many factors that can affect the amount of power that your computer system will require. It is suggested that the load placed
on the battery outlets not exceed 80% of the unit's capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure
the battery's maximum charge capacity, it is recommended that you charge the battery for at least 8
hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet,
the battery will automatically charge whether the UPS is turned on or off.
2. Note: This UPS is designed with a safety feature to keep the system from being turned on during
shipment. The first time you turn the UPS on, you will need to have it connected to AC power or it will not
power up.
3. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup
into the battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump
or other large electrical devices into the "Battery and Surge Protected Outlets". The power demands of these devices may overload
and damage the UPS.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit
breaker and does not service equipment with large electrical demands (e.g. air conditioner, copier, etc...). The
warranty prohibits the use of extension cords, outlet strips, and surge strips.
5. Press the power switch to turn the unit on. The Power On indicator light will illuminate and the unit will "beep".
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the
UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed
and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every
three months to ensure battery life.
8. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
BASIC OPERATION
DESCRIPTION
1
Power Switch
Used as the master on/off switch for equipment connected to the battery power supplied outlets.
(Please refer to the Function Setup Guide for more information.)
2
Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3
LCD module display
The LCD display shows all the UPS information using icons and messages. For more information please review
the "Definitions for Illuminated LCD Indicators" section below.
4
LCD Display Toggle/Selected Switch
The switch can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time.
Click the button to scroll down the function menu. Pressing the button for 3 seconds will keep the LCD display always on or
turn the LCD display off while in AC/Utility power mode. For more information, please refer the Function Setup Guide.
5
USB Charging Ports (except for LX1100G-FC)
The USB Charging ports provide 5V 2.1A power output.
www.cyberpowersystems.com
and go to the Software
6
Battery and Surge Protected Outlets
The UPS has five battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted
operation of your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum,
sump pump or other large electrical devices into the "Battery and Surge Protected Outlets". The power demands of these devices
may overload and damage the unit.)
7
Full-Time Surge Protection Outlets
The UPS has five surge suppression outlets.
8
Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.
9
USB Ports to PC
The USB port allows connection and communication between the USB port on the computer and the UPS unit.
10 Communication Protection Ports
Communication protection ports, bi-directional, will protect a 10/100/1000 Ethernet connection (RJ45).
11 Wiring Fault Indicator (red)
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.
If this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS
will not provide surge protection without being plugged into a grounded and properly wired wall outlet.
12 Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver.
13 Outlets Designed for AC Adapters
The unit has two outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB1270X2C for the
LX1100G-FC / LX1325GU-FC, and CyberPower / RB1290X2 for the LX1500GU-FC.
2.
CAUTION! Risk of Energy Hazard, 24 V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as
chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
3.
CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
4.
CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.
CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed
5.
when working on batteries:
1) Remove watches rings, or other metal objects.
2) Use tools with insulated handles.
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDINGTO LOCAL REGULATIONS.
BATTERY REPLACEMENT PROCEDURE:
1. Turn off and unplug all connected equipment.
2. Turn the UPS off and unplug it from the AC power source.
3. Turn the UPS on its side.
4. Remove two retaining screws located on the bottom of the UPS.
5. Slide the battery compartment cover completely off of the unit.
6. Remove the battery which is located on the right side from the compartment.
7. Disconnect the battery wires from the right side of the battery.
8. Slide the remaining battery from left to right and remove it from the compartment.
9. Disconnect the battery wires from the remaining battery.
10. Install the "left side" replacement battery by connecting the yellow wire (+) to the red connector from the battery and the black wire (-) to
the black connector from the battery. Place the battery into the left side of the compartment.
11. Install the "right side" replacement battery by connecting the red wire (+) to the red connector from the battery and yellow wire (-) to the
black connector from the battery. Place the battery into the right side of the compartment. Note: Only new batteries should be used for
replacement and both batteries should be replaced at the same time to insure maximum life span.
12. Slide back the battery compartment cover and tighten the retaining screws.
13. Recharge the UPS for 8-16 hours to fully charge the battery.
Yellow Wire to (+) Red Connector
Black Wire to (-) Black Connector
REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries
collect used batteries for recycling, as required by local regulations.
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
1.
INPUT voltage meter:
This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed, through the use
of automatic voltage regulation, to continuously correct output voltage to connected equipment to a safe 110/120 voltage output range. In
the event of a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120
output voltage. The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.
2.
OUTPUT voltage meter:
This meter measures, in real time, the AC voltage that the UPS system is providing to the computer, such as normal line mode, AVR
mode, and battery backup mode. (Note: The OUTPUT voltage meter shows the status of the battery backup outlets.)
3.
ESTIMATED RUNTIME:
This displays the run time estimate of the UPS with current battery capacity and load.
4.
NORMAL icon:
This icon appears when the UPS is working under normal conditions.
5.
BATTERY icon:
During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS
is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS's
batteries are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system
down.
6.
AVR (Automatic Voltage Regulation) icon:
This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power. This is a normal, auto-
matic operation of your UPS, and no action is required on your part.
7.
SILENT MODE icon:
This icon appears whenever the UPS is in silent mode. The buzzer does not beep during silent mode until the battery
reaches low capacity.
8.
OVER LOAD icon:
This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug some of your
equipment from the battery-supplied outlets until the icon turns off and the alarm stops.
9.
FAULT: This icon appears if there is a problem with the UPS. Press the POWER button to turn the UPS off.
F01: Battery Mode or AC/Utility Power Mode Overload fault
(Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)
F02: Battery Output Short fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)
F03: Charger Fault (Contact CyberPower Systems for support.)
F04: Internal Fault (Contact CyberPower Systems for support.)
10. BATT. CAPACITY meter:
This meter displays the approximate charge level (in 20% increments) of the UPS's internal battery. During a blackout or severe brownout,
the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.
11. LOAD CAPACITY meter:
This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets.
For more information about functions setup, please refer to the Function Setup Guide.
Red Wire to (+) Red Connector
Yellow Wire to (-) Black Connector
The LCD display indicates a variety of UPS
operational conditions. All descriptions apply
when the UPS is plugged into an AC outlet
and turned on or when the UPS is on battery.
K01-0000439-00

Advertisement

loading

Summary of Contents for CyberPower LX1100G-FC

  • Page 1 1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB1270X2C for the LX1100G-FC / LX1325GU-FC, and CyberPower / RB1290X2 for the LX1500GU-FC. CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery. CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in CAUTION! Risk of Energy Hazard, 24 V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns. accordance with the National Electric Code, ANSI/NFPA 70. CAUTION! Do not dispose of batteries in a fire. The batteries may explode. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. patient care. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation when working on batteries: from the aquarium can cause the unit to short out. 1) Remove watches rings, or other metal objects. DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
  • Page 2 2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly con- SYSTEM FUNCTIONAL BLOCK DIAGRAM nected to the Product and not “daisy-chained” together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. Any such installation voids the Limited Warranty. 3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it. 4. The Product must have been used at all times within the limitations on the Product’s VA capacity. The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage spikes or impulses from lightning or other power transients. If it can be shown that a voltage spike lasting longer than 1ms has occurred, the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void. CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following: 1. Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software. 2. Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and code-compliant 120 volt CyberPower GreenPower UPS Technology ™ power lines in the United States and Canada; transients, surges or spikes on standard telephone land lines, PBX telephone equipment lines or Base 10T Ethernet lines, when properly installed and connected. (This exclusion applies, for example, to fluctuations in data transmission or reception, by CATV or RF transmission or fluctuations, or by transients in such transmission.) Advanced Energy-Saving Patented Bypass Technology 3. Damage from any circumstance described as excluded above with respect to the Product. CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to 4. Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of either the product or the 75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models Connected Equipment. constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry of 5. CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee. CyberPower a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly increased...
  • Page 3 LES BATTERIES USAGÉES DOIVENT ÊTRE MISES AU REBUT CONFORMÉMENT AUX RÈGLEMENTATIONS LOCALES. INTRODUCTION Merci d’avoir choisi un onduleur CyberPower Systems. Cet onduleur est conçu pour fournir une protection de l’alimentation, un fonctionnement PROCÉDURE DE REMPLACEMENT DE LA BATTERIE : et des performances inégalés au cours de la durée de vie du produit.
  • Page 4 LX1500GU-FC Si le produit comporte un défaut de matériel ou de fabrication, alors CyberPower réparera ou remplacera le produit à ses dépends, ou bien, si CyberPower est incapable de ou décide de ne pas réparer ou remplacer le produit (s’il est défectueux) dans une limite de temps raisonnable, Capacité...