SELECTING A MOUNTING LOCATION

1. Give consideration to the weight of the unit when
operating, i.e. when filled with water. Operating weight of
the Everpure
Conserv
®
• 58 lbs (26 kgs)
2. The location should allow for:
• The Conserv 75E RO System may be wall mounted or
set on its base .
• Adequate space for "in" and "out" water line
connections.
• Be near a drain for flushing.
• Accessible to a wall plug.
3. The inlet water supply must meet the requirements listed
in the section "Operating Specifications".
DIMENSIONS
10.20 in
(259 mm)
Figure 1
2
EVERPURE
CONSERV
®
• Phillips Screwdriver
• Towel
• Safety Glasses
• Drill Bits: 1/8", 1/4" and
3/8"
75E System is approx.:
®
16.95 in
(431 mm)
18.70 in
(475 mm)
75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
®

OPERATING SPECIFICATIONS

WARNING: Before installing the system, make certain
your water supply complies with the
following operating specifications. Failure
to do so may reduce the effectiveness of
the system and will void the warranty.
Consult your local water treatment
utility or a certified water testing lab to
determine the quality of your water.
Temperature:
Dynamic Operating
Pressure:
Maximum Static
Pressure
Total Dissolved Solids:
Sulfide, Iron and
Manganese:
Water Supply pH Limits:
Turbidity:
For cold water use only.

SAFETY INSTRUCTIONS

NOTE: This appliance can be used by children aged
from eight (8) years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given supervision
or instruction concerning use of the appliance
in a safe way and understand the hazards
involved.
NOTE: The appliance is only to be installed in
locations where its use, maintenance and
cleaning is restricted to trained adult
personnel. No one should play with the
appliance.
NOTE: Children should be supervised to ensure that
they do not play with the appliance.
NOTE: Cleaning and user maintenance shall not be
made by children without supervision.
NOTE: The appliance is not suitable for installation in
an area where a water jet could be used.
NOTE: If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order to
avoid a hazard.
WARNING: Installation shall comply with applicable
local, state, and national plumbing and
electrical regulations.
32 - 100°F (0 - 37.7°C)
40 - 85 psi (2.7 - 5.8 bar, 0.27 - 0.58
MPa), non-shock
125 psi (8.6 bar, 0.86 MPa)
1,000 ppm maximum
Less than 0.1 ppm
4 to 11
1.0 NTU maximum