3. Tubing should be cut squarely. Internal and external
burrs should be removed. Place a mark on tubing 5/8"
(1.6 cm) from end on 1/4" tubing or 3/4" (1.0 cm) from
end on 3/8" tubing.
4. Wet the end and insert tubing until the mark is flush with
the quick-connect fitting.
5. OPEN the cold water supply until it comes to a stop.
OPEN the tank valve and CLOSE the application valve. If
leaks persist, call Technical Support.
No Flow or Slow Flow from the Brine (Reject) Line (Less
than 6 fl. oz. or 180 mL per minute)
NOTE: Before checking brine (or reject) flow, make sure the
unit is producing water by turning the valve on the
storage tank OFF and OPENING the application valve.
Water should drip from valve.
1. Replace the prefilter cartridge according to the
"Changing the Cartridge Instructions" and recheck the
brine (or reject) flow rate.
2. If the prefilter cartridge is not at fault, the brine (or
reject) flow controller could be clogged. Call
Technical Support.
High TDS in Product Water
1. If high TDS (Total Dissolved Solids) is detected in the
blended water, the RO cartridge may need to be replaced
or the reject flow control tubing may be clogged. If this is
a new installation, call Technical Support.
2. Otherwise, draw 1 gal (3.8 L) of water from the unit. After
10 minutes, run water from the blended water port and
test the water again.
3. Determine when you last changed the RO cartridge and
call Technical Support.
Limited Flow at the Application Equipment Valve
1. Turn OFF water supply to system.
2. OPEN the application valve to turn on flow.
3. Unscrew the black cap at the base of the storage tank to
expose air valve. Use a small air compressor or bicycle
pump to slowly add air to the storage tank. This will
force the water out of the storage tank through the valve.
Continue to slowly add air until water stops coming out
of the valve.
4. Turn OFF the application equipment valve.
5. Using an air pressure gauge, adjust the pressure in the
storage tank to 25 psi (1.72 bar, 0.17 MPa).
6. Replace the black cap.
7. OPEN the incoming water valve until it comes to a stop.
Let the system run one (1) to three (3) hours to fill the
tank. A full tank weighs approximately 29.4 lbs (10.2 kgs)
pounds. If performance has not improved, call
Technical Support.
EVERPURE
CONSERV
®
75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
Sudden Return of Taste and Odor
If shortly after complete servicing, noticeable taste and odors
return, contact Technical Support.
If you are experiencing a problem not listed in this manual,
shut OFF the water supply and CLOSE the tank valve. Call
Technical Support.
NOTES
Check for compliance with state and local laws and
regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
For installations in Massachusetts, the Commonwealth of
Massachusetts Plumbing Code 248 CMR shall be adhered
to. Consult your licensed plumber for installation of the
system. This system and its installation must comply with
state and local regulations.
Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Substances that may be reduced are not necessarily in your
water. Filter must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
The tested efficiency rating for this system is 37.63%.
Efficiency rating means the percentage of the influent water
to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage.
The tested recovery rating is 53.94%. Recovery rating means
the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis
treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
Daily Production Rate: 50.51 gpd (191.20 Lpd)
This reverse osmosis system contains a replaceable
component critical to the efficiency of the system.
Replacement of the reverse osmosis component should
be with one of identical specifications, as defined by the
manufacturer, to ensure the same efficiency and contaminant
reduction performance.