Advertisement

Quick Links

esense Rise
user guide
esense Rise user guide (E1206-3200/-3700) I version 2.00 I 02-03-2020

Advertisement

Table of Contents
loading

Summary of Contents for Indes esense Rise

  • Page 1 Rise user guide esense Rise user guide (E1206-3200/-3700) I version 2.00 I 02-03-2020...
  • Page 2 Your supplier Name Address Zip Code City Country Phone Email esense is a product by: Indes Production Management T +31 (0)53 4803920 Pantheon 28 info@esense-moves.com 7521 PR Enschede www.esense-moves.com The Netherlands esense Rise user guide (E1206-3200/-3700) I version 2.00 I 02-03-2020...
  • Page 3: Table Of Contents

    Table of contents Introduction ............................4 About this guide ........................... 5 Definitions ........................... 5 Specific sections .......................... 5 Important safety instructions ....................... 6 Certification ............................7 Product description ..........................7 Product models ........................... 7 Main components ........................8 Component overview ........................8 User interface .............................
  • Page 4 Product label ..........................25 Warranty ............................26 Distribution and authorization list ....................27 Revision list ............................ 27...
  • Page 5: Introduction

    Netherlands. With over 30 years of experience in development and production of products for the Cure and Care market, Indes creates products people rely on. By gaining full insight in user needs we aim to develop products that improve the quality of everyday life.
  • Page 6: About This Guide

    Specific sections Caution! Text in red boxes describes important instructions and potentially dangerous situations and shall be read carefully. Please contact Indes for clarification in case the text raises any questions. Notice! Text in blue boxes describes points of attention and other issues that are important to be aware of before and during use of the patient lift.
  • Page 7: Important Safety Instructions

    Do not expose the lift to temperatures below -5°C and over 50°C. Caution! Use the patient lift exclusively with slings of the ‘esense’ or ‘SlingCare’ brand supplied by Indes. These can be recognised by a label with the text ‘esense’ or ‘SlingCare’. Caution! The esense power assist functionality is activated by sensitive sensors in the pushbar.
  • Page 8: Certification

    Indes shall not be held responsible for any damage and potential resulting consequential damage in case of intentional damage, overdue maintenance, improper use and deviation from the instructions set out in this user guide. 4 Certification All esense products are marked with a CE certification. The products are classified as class I of the Medical Devices directive MDD 93/43/EEC.
  • Page 9: Main Components

    Main components esense Rise manual esense Rise 1. Base 6. Controller box 2. Mast 7. Hand control 3. Lifting frame 8. Pushbar 4. Footplate 9. Battery charger 5. Shin rest 10. esense drive Component overview Base (1) The base of the patient lift is equipped with 4 castor wheels: 2 braked rear castors and 2 unbraked front castors.
  • Page 10 On the outside of the controller box a battery charger plug, USB port, connector for the hand control and an emergency switch are located. Also the pushbar is connected to the controller box. Hand control (7) The hand control is connected to the controller box through a flexible spiral cord.
  • Page 11: User Interface

    6 User interface Hand control The patient lift is controlled using the hand control. It can be taken out of the bracket and held in hand, making it possible to control the lift from many different positions. Indication LEDs 1 Battery level indication 2 Service indication 3 On-off indication User controls...
  • Page 12: Service Indication

    Service indication Periodic maintenance notification When the service indication LED (2) blinks 3 times when the lift is switched on, it is time for periodic maintenance. During start-up the current date is compared to the date for next periodic maintenance that is set in the system.
  • Page 13: Emergency Switch

    Emergency switch If the lift behaves unpredictably it is possible to immediately switch off all motors by pressing the red emergency switch (N) on the controller box. When the button is pressed all LEDs on the hand control start blinking and a beep signal sounds. This also happens if the lift is switched on while the emergency switch is already pressed.
  • Page 14: Battery Indication On Hand Control

    Notice! Even when the lift is not used the battery will drain slowly. A fully discharged battery can get damaged. Therefore it is advised to fully charge the battery at least once every 3 months. Notice! The battery can be charged at any time. It does not harm to charge it when it is not yet fully discharged.
  • Page 15: Driving / Manoeuvring

    Driving / manoeuvring The lift is easily moved by pushing and pulling the pushbar with your hands. In lifts with esense drive functionality the pushbar is equipped with sensors registering the force put on the handle. The sensors measure both the magnitude and the direction of the force that it is exerted.
  • Page 16: Leg Adjustment

    6.10 Leg adjustment The patient lift is standard equipped with electrical leg adjustment. This improves accessibility to the patient and makes it possible to drive the lift closer. The electrical leg adjustment is activated and controlled using the corresponding buttons on the hand control.
  • Page 17: Use Of Slings

    The patient lift shall be used in combination with a sling that supports the patient during the transfer. The sling is attached to the lifting frame using Visual Clips. Notice! Use the patient lift exclusively with ‘esense’ or ‘SlingCare’ slings supplied by Indes. The slings are recognised by the ‘esense’ or ‘SlingCare’ label. Notice!
  • Page 18: Performing Patient Transfers

    7 Performing patient transfers Notice! Always check the patients’ medical file to learn if the patient has any limitations regarding patient lift transfers. Caution! The Rise is an active patient lift. This type of lift is designed for patients with a limited stand up function but good body stability.
  • Page 19 Caution! Pay attention that the sling stays in place and does not shift during the transfer. Caution! In case a patient becomes unwell or indicates to be experiencing any discomfort, immediately stop the transfer and bring the patient back in his original position. Notice! As soon as you release the height adjustment button on the hand control the lifting motion will immediately stop.
  • Page 20: Service And Maintenance

    8 Service and maintenance Product lifespan If used and maintained correctly the average lifespan of the patient lift shall be 8 years minimum. Some parts, like e.g. slings, shin rest, battery and esense drive, are highly sensitive to wear and might have to be replaced during the total lifespan.
  • Page 21 In accordance with NEN-EN ISO 10535 the slings need to be inspected by an authorised person at least twice a year. For slings used or cleaned above average, more frequent inspection is advised. Notice! It is required to keep a maintenance log in which all relevant observations regarding defects, damage and wear are reported.
  • Page 22: Quick Debugging Guide

    9 Quick debugging guide The patient lift is not working 1. Check if the lift is switched on by pressing the on-off switch. The on-off LED has to light up green. If it does not then switch the system off and on again. 2.
  • Page 23: The Lift Functionality Is Not Working

    The lift functionality is not working Notice! Be aware that the lifting motion is deactivated if the weight capacity of the lift is (far) exceeded. Check if the weight of the patient does not exceed the maximum. Notice! If necessary, use the emergency lowering function to manually lower the patient (see paragraph 6.11 ‘Emergency lowering’).
  • Page 24: Technical Specifications

    10 Technical specifications 10.1 Patient lift Lift dimensions Rise Length of the base (frame) 90 cm Height of the base 11,5 cm Min. clearance to floor 3,7 cm Min. internal width 46 cm Max. internal width frame – closed legs 52,7 cm Max.
  • Page 25: Battery

    Protection grade – hand control IPx2 Duty cycle 10% max * One complete lifting motion is defined as a movement from the lowest possible point up to the highest possible point and back. 10.2 Battery Battery Manual esense drive Guaranteed battery lifetime in charging cycles 500 x 500 x Battery type...
  • Page 26: Product Label

    11 Product label Each patient lift has an identification label, located below the controller box. Maximum lifting weight Article number Serial number Notice! Displayed label is an example and may differ from the actual label on the patient lift.
  • Page 27: Warranty

    12 Warranty The manufacturer guarantees a 2 year warranty on the patient lift. For batteries a warranty of 500 charge cycles or 2 years is applicable. The manufacturer reserves the right to make changes to the product, deviating from what is described in this guide.
  • Page 28: Distribution And Authorization List

    (1, 6.5, 6.9) esense is a product by: Indes Production Management T +31 (0)53 4803920 Pantheon 28 info@esense-moves.com 7521 PR Enschede www.esense-moves.com The Netherlands esense Rise user guide (E1206-3200/-3700) I version 2.00 I 02-03-2020...

Table of Contents