8. SPECIFICATIONS

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VEC020
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 VDC
Boost Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300 Instantaneous Cranking Amps
Peak Ampere Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .900 Peak Amps
Battery Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sealed, high energy density lead-acid,
Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 volt 0.2 Amp Krypton
Booster Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .#6AWG welding cable with
Accessory Socket Self-Resetting Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Amps
Charging Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 volt DC
Adapter/Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110/120 Volt AC (500mA,
Reverse Polarity Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 Volts (min)
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.5 in. (21 cm)
DEPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.0 in (12.5 cm)
WIDTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.8 in(24.5 cm)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.7 Lbs (4.84 Kg
9. REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector
(954) 584-4446.

BULB REPLACEMENT

Tools needed - small Phillips screwdriver. Replacement bulbs are available from Vector
Customer Service Department; call (954) 584-4446 ext. 19.
1. Unscrew (counterclockwise) and remove two Phillips screws.
2. Remove the lens cover.
3. Remove the burned-out bulb.
4. Replace with a new bulb (12 volt 0.2 amp Krypton bulb) available from Vector
Customer Service Department; call (954) 584-4446 ext. 19
5. Snap the lens cover back into place.
6. Replace (clockwise) the screws and carefully tighten. Do not over tighten!
14
rechargeable, maintenance-free,
12 volt DC, 15 Amp-hour
350 Amp copper clamps
12 Volt DC Output)
)
®
Customer Service:
®
®
SAFETY INFORMATION
WARNING STATEMENTS IDENTIFY CONDITIONS OR PRACTICES THAT MAY
RESULT IN PERSONAL INJURY OR LOSS OF LIFE.
1. When working with lead acid batteries, always make sure immediate assistance is
available in case of accident or emergency.
2. Protective eyewear must be worn when using this product; contact with battery acid may
cause blindness and/or severe burns; be aware of first aid procedures in case of
accidental contact with battery acid.
3. There is a risk of explosive gases being released when lead acid batteries are being
charged or discharged. Failure to follow instructions may cause property damage,
explosive hazard, and/or personal injury.
4. Make sure the Safety Switch is Off before connecting battery clamps to discharged
battery. This will enable the polarity alarm to function.
5. When connecting the battery clamps to a discharged battery, and an alarm sounds,
do NOT turn on the Safety Switch - the polarity is reversed. Interchange battery clamps
before turning the Safety Switch ON.
6. When charging unit from a 110/120 volt AC electrical outlet in any wet or damp area,
make sure that the outlet used is protected by a Ground Fault Interrupt (GFI) Switch.
7. When charging the unit near water, do not allow the electrical cords and outlets to get
wet or come near water; electrical shock could result!
8. Jumpstart procedures should only be performed in a safe, dry, well-ventilated area.
9. Always store battery clamps in built-in holsters when not in use. Never touch battery
clamps together; this can cause dangerous sparks, power arcing, and/or explosion.
10. When using this unit in proximity to the vehicle's battery and engine, stand the unit on
a flat, stable surface, and be sure to keep all clamps, cords, clothing and body parts
away from moving vehicle components.
11. Do not wear vinyl clothing when jumpstarting a vehicle; friction can cause dangerous
static electricity sparks. Remove all jewelry or metal objects that could cause short
circuits or react with battery acid.
12. Always disconnect the negative (Black) jumper cable first; followed by the positive
(Red) jumper cable.
13. Never allow red and black clamps to touch each other or another common metal
conductor; this could cause damage to the unit and/or create sparking/explosion
hazard. Always store battery clamps in built-in holsters when not in use.
14. Do not expose battery to fire or intense heat as it may explode. Before disposing of
the battery, protect exposed terminals with heavy-duty electrical tape to prevent
shorting (shorting can result in injury or fire).
15. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle's battery system.
16. Keep unit out of reach of children (whether stored, or in use).

FIRST AID:

1. SKIN: If battery acid comes in contact with skin, rinse immediately with water, then
wash thoroughly with soap and water. If redness, pain, or irritation occurs,
seek immediate medical attention.
2. EYES: If battery acid comes in contact with eyes, flush eyes immediately for a minimum
of 15 minutes; seek immediate medical attention.