Watts SentryPlus 113RFP Installation, Operation And Maintenance Manual
Watts SentryPlus 113RFP Installation, Operation And Maintenance Manual

Watts SentryPlus 113RFP Installation, Operation And Maintenance Manual

Universal upgrade kit

Advertisement

Quick Links

Installation, Operation, and
Maintenance Manual
SentryPlus™ Alert
Universal Upgrade Kit

Table of Contents

Table of Contents
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Understanding Safety Information . . . . . . . . . . . . . . . . . . . . 2
Understanding Safety Information . . . . . . . . . . . . . . . . . . . . 2
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
List of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Required Tools and Materials for Installation . . . . . . . . . . . . . . 2
Installation and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring/Retrofitting the junction box . . . . . . . . . . . . . . . . . . . 4
Installing the Wireless Node . . . . . . . . . . . . . . . . . . . . . . . . . 6
Start-up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
WARNING
!
Read this Manual BEFORE using this equipment.
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
can result in death, serious personal injury, property
damage, or damage to the equipment.
damage, or damage to the equipment.
Keep this Manual for future reference.
Keep this Manual for future reference.
IOM-UPGRADEKIT-SentryPlusAlert

Advertisement

Table of Contents
loading

Summary of Contents for Watts SentryPlus 113RFP

  • Page 1: Table Of Contents

    IOM-UPGRADEKIT-SentryPlusAlert Installation, Operation, and Maintenance Manual SentryPlus™ Alert Universal Upgrade Kit WARNING Read this Manual BEFORE using this equipment. Read this Manual BEFORE using this equipment. Failure to read and follow all safety and use information Failure to read and follow all safety and use information can result in death, serious personal injury, property can result in death, serious personal injury, property damage, or damage to the equipment.
  • Page 2: Important Safety Information

    • Can be installed with any existing RPZ backflow preventer BEFORE installing, setting up, using, or servicing. • Can be used to upgrade an existing Watts LFF113RFP ACV to • Keep the manual available for easy access and future support SentryPlus Alert Technology reference.
  • Page 3: Installation And Operation

    Installation and Operation Solenoid Operation (For Existing LFF113RFP Installations Only) The Solenoid is prewired to the existing Junction Box, and must be rewired by a certified electrician. The solenoid is equipped with a Solenoid Bypass valve (normally closed) which manually closes the Main Valve when engaged.
  • Page 4: Wiring/Retrofitting The Junction Box

    Installation and Operation Wiring/Retrofi tting the junction box Wireless Node Junction Box Cellular Wired to Connection Terminals to Internet 3 & 4 Power Relay with Red LED Indicator POWER CELLULAR FLOOD PROG RESET TEST FLOOD AC Power FLOOD Adapter +12Vdc Incoming Flow Solenoid...
  • Page 5 Installation and Operation Adjusting the Time Delay • Adjust the time delay to avoid alert / valve closure due to inter- mittent or nuisance relief valve discharge. The delay is adjust- able from 0 seconds to over 1 hour. • Adjust the time delay by using the delay adjustment dial in the Junction Box.
  • Page 6: Installing The Wireless Node

    Installation and Operation Installing the Wireless Node WARNING Ensure all power supply to the Wireless Node is turned off before making any connections to the Wireless Node. Failure to do so may result in electrocution, personal injury, and/or death. 1. Identify preferred location for mounting Wireless Node. The Wireless Node must be located away from large metal com- ponents and structures that may block the cellular signal.
  • Page 7: Registering Your Device And Alert Configuration

    Installation and Operation Wireless Node Operation NOTICE 1. Start-Up – Upon start-up, the Power LED (7) will light up If there is no Cloud connection, then notifications will not be a steady green to indicate power is supplied. The Wireless sent to the user via Syncta.
  • Page 8: Start-Up Instructions

    ⁄ Limited Warranty: Watts (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.