The mobile initiated sequence test is similar to the cell
initiated test except the cellular telephone is placing the
call.
This screen is accessed through the main Tone Memory
screen.
See figure 7.
FIGUHE 7. MOBILE INITIATED SEQUENCE TEST DISPLAY
MOBILE !NIT SEQ TEST
1) EXIT
SEL)
2)
START TEST
CHAN
4) 560
PL)
0
SAT)
3
The selections possible are 1) EXIT, and 2) START TEST.
These
selections are possible if the cursor is in the home position
at the top of the screen.
A '1' will return the screen back to
the Tone Memory screen.
A
'2'
will start the test.
Help messages describing the blocks of the thermometer sequence
can be accessed by moving the cursor to the line underneath the
squares and advancing to the right by keying any number 1 to 9.
The squares on the top row of the thermometer display indicate
actions that will be taken by the R2008C during the test.
The
squares on the next line indicate actions that the mobile takes
are perceived by the R2008C.
Note that the first square is
filled in since the R2008C begins an FOCC data stream upon entry
into the mobile initiated sequence test screen.
The cellular
telephone should scan onto the data stream and the 'NO SVC' light
should go out.
If a foreign system ID was entered, the 'ROAM'
light will light.
The test can be started at any time.
Once commenced, the R2008C
will wait for a service request from the car phone. Enter the
number
to be called into the cellular telephone. Allow the 'NO
SVC' light to go out, then depress the 'SEND' key, the R2008C
will receive the service request message and display the
22