Start-Up Procedure
User programming (cont'd)
3. Adjust Regeneration Time: Press the Extra Cycle button to advance to next option. This
setting determines the time of day that the unit will enter the regeneration cycle. The most
common / default setting is 12:30 AM. IMPORTANT: this regeneration time should be offset
from any water softener's regeneration time by at least 2 hours to insure adequate regenera-
tion pressure.
Control programming is now complete. Press the extra cycle button, and the control will
exit from the programming mode and resume normal operation.
MAINTENANCE NOTE:
This filter uses a sacrificial media of calcium carbonate in order to neutralize water PH. Over
time, this media will diminish, and the filter will require additional media to be added. The
amount of media used will vary dependent on water usage, and PH. Check media level annual-
ly by removing module (per instructions on next page) and visually inspecting. If the media
level is below 25% of the tank level, contact your installing dealer for further service.