MAINTENANCE AND CARE
Regular lubrication is a prerequisite for the proper functioning of your pneumatic tool and a long ser -
vice life. The following lubrication options are available:
Using a mist lubricator:
A complete maintenance unit includes a mist lubricator and is attached to the com-
o
pressor (not included).
Using a line oiler:
A line lubricator is installed in the immediate vicinity of the tool (approx. 50 cm distan-
o
ce), which supplies the tool sufficiently with oil.
If the pneumatic tool has been out of operation for several days, you must add 5-10
o
drops of special tool oil to the compressed air connection before switching it on.
By hand:
If your system has neither a maintenance unit nor a line lubricator, you must add 3 - 5
o
drops of special tool oil to the compressed air connection before each commissioning
of your impact wrench.
Store your air tool only in dry, frost-proof rooms.
TOOL: ROD GRINDER
ATTENTION: Never point the rotating end of the tool towards yourself or other persons. Connect the
unit to the air supply hose.
INTENDED USE
Das druckluftbetriebene Gerät eignet sich zum Glätten von Oberflächen bzw. zum Entfernen von
Beschichtungen auf Oberflächen.
Nicht für die industrielle Bearbeitung von Teilen geeignet.
OPERATING INSTRUCTIONS
Before connecting the compressed air hose to the unit, make sure that the operating lever is NOT
pressed!
Always secure the workpiece to be handled before handling it with the pneumatic tool. Never hold
the workpiece with one hand while operating the tool with the other!
Never exert too much pressure on the workpiece, this could result in a recoil with unforeseeable
consequences (injuries)!
All attachment replacement, adjustment and maintenance work may only be carried out with a
separate compressed air hose.
MAINTENANCE AND CARE
Regular lubrication is a prerequisite for the proper functioning of your pneumatic tool and a long ser -
vice life. The following lubrication options are available:
Using a mist lubricator:
A complete maintenance unit includes a mist lubricator and is attached to the com-
o
pressor (not included).
Using a line oiler:
A line lubricator is installed in the immediate vicinity of the tool (approx. 50 cm distan-
o
ce), which supplies the tool sufficiently with oil.
If the pneumatic tool has been out of operation for several days, you must add 5-10
o
drops of special tool oil to the compressed air connection before switching it on.
By hand:
If your system has neither a maintenance unit nor a line lubricator, you must add 3 - 5
o
drops of special tool oil to the compressed air connection before each commissioning
of your impact wrench.
Store your air tool only in dry, frost-proof rooms.
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de