Activity Indicator
(Green)
Blinking at 4 Hz
Steady on
Blinking at 1 Hz
Off
Steady on
NVMe Drive Indicators
Figure 5-29 NVMe drive indicators
Issue 03 (2020-04-20)
Fault Indicator
(Yellow)
Off
Blinking at 1 Hz
Blinking at 1 Hz
Steady on
Steady on
If the VMD function is enabled and the latest VMD driver is installed, the
NVMe drives support surprise hot swap.
Table 5-9 Description of NVMe drive indicators (VMD enabled)
Activity
Indicator
(Green)
Off
Steady on
Blinking at 2 Hz
Off
Off
Steady on/Off
Copyright © Huawei Technologies Co., Ltd.
Description
Data is being read or written normally,
or data on the primary drive is being
rebuilt.
The drive is being located.
The data on the secondary drive is
being rebuilt.
A member drive in the RAID array is
removed.
The drive is faulty.
Fault Indicator
Description
(Yellow)
Off
The NVMe drive cannot be detected.
Off
The NVMe drive is working properly.
Off
Data is being read from or written
to the NVMe SSD.
Blinking at 2 Hz
The NVMe drive is being located.
Blinking at 8 Hz
The data on the secondary NVMe
drive is being rebuilt.
Steady on
The NVMe drive is faulty.