Led microbars

Advertisement

Caution: When drilling into any vehicle surface, make sure the area
is free from any electrical wires, fuel lines, vehicle upholstery, etc.
that could be damaged
Permanent Mounting:
1. Select the desired location on a flat surface for the
Microbar to be mounted. The visibility of the flash and
ease of wiring access should be taken into
consideration in the selection of the mounting location.
2. Drill Ø13mm hole for bolt in central location.
3. Remove nut/ shakeproof washer/ washer from bolt. (rubber
spacer to stay on bolt above mounting surface)
4. Place sponge gasket in position on vehicle roof.
5. Place lightbar on roof with wires and bolt through the hole.
6. Ensure bolt head is located correctly in base moulding.
7. Re-apply washer/ shakeproof washer/ nut on underside of
mounting surface and tighten nut to 5Nm.
8. Connect the wires as shown in the wiring section (see Figure 2)
!
WARNING!
Failure to follow these instructions can result in fire or injury from excessive heat build up.
Operator is responsible for ensuring auxiliary plug fits correctly into auxiliary power plug outlet used.
For proper operation, verify auxiliary power outlet circuit is rated to supply a minimum of 10 amps. (See specifications section for rated current in amperes).
Do not exceed the current rating for the auxiliary power outlet recommended by vehicle manufacturer.
Keep auxiliary plug and outlet clean and free of debris.
Do not use the auxiliary plug when wet.
Insert auxiliary plug fully into the outlet for proper connection.
Grasp auxiliary plug, NOT cord, to remove from outlet.
Remove auxiliary plug completely from outlet when light is not in use.
Important! Disable power before wiring up the Microbar.
Magnetic Mount Installation for 5500 Series:
1. Remove round black stickers for Magnetic placement
2. Remove lens screws, then remove lens.
3. Unclip and remove wire harness
4. Position vacuum magnets, place, and tighten screws.
5. Insert pinned end of cable through the wire harness hole from the
bottom of the base. Pull at least 6 inches of slack.
6. Turn pins crimp side up, and insert pins into connector as shown in
Figure 3.
7. Place zip-tie 1.0" from base of the connectors shown in Figure 4. Zip-tie
must not slide on cord.
8. Trim excess zip-tie.
9. Clip connector to the PCA board and pull slack until zip-tie touches base.
10.Install lens, reverse of removal.
11.Slide o-ring onto screw until it reaches head, before placing into lens.
If o-rings are damaged, replace with new ones.
Wiring:
The wiring for the permanent mount Microbar is as shown in Figure 5. All
wiring should be a minimum of 18AWG. The positive line must have a 5 amp
fuse, as shown. A switch may be used to control the on/off function.
FIGURE 2
Page 2 of 4
P/N 920-0558-00 (Rev A) 2016-12-21
© 2016 at ECCO
!
WARNING!
Maximum recommended vehicle speed for safe operation using
the Mount model is 65 mph (104 km/h), when fitted to the center
of a vehicle roof of steel construction. Higher speeds could
cause the mount to fail, resulting in the minibar flying off of
the vehicle, which could cause damage to other vehicles, and
injury or death to the passengers. The magnet mount is not
intended as a permanent mounting for the minibar. The magnet
mount unit must be mounted on a flat smooth magnetic surface
(i.e. no fiberglass, ribbed style roofs, etc.). Ensure that the
magnet is kept clean.
.
Note: Operating the Microbar without the lens installed on this
product will result in damage that will not be covered under warranty.
NOTE: Operating the vehicle without the outer lens installed on the
product may result in damage that will NOT be covered under
warranty.
Flash Mode Selection:
Flash patterns can be selected on permanent mount Microbar by
touching the yellow wire to the red power wire for less than a second.
Contacting the yellow and red wires for longer than a second toggles to
the preceding flash pattern. The VM models have flash pattern select
via a momentary switch on the cigarette plug.
The 5550 permanent mount models sync with other compatible ECCO
products via the blue wire:
1. Determine the desired style of flash pattern for each unit and seteach
unit individually (without the BLUE wires connected together) to avoid
confusion. It is also strongly recommended that the same style of
flash pattern be used on all units to produce the most effective
warning pattern. (NOTE: Phases A and B for each style of flash
pattern in the table denote the relative timing between units
connected in synchro-nizing installation. To operate simultaneously,
each unit must be set to the same phase (A + A or B + B); to operate
alternately, units must be set to have the opposite phase
(A + B or B + A)).
2. Connect the BLUE (SYNC) wires together and check that the units
are flashing in a synchronized manner as expected. If a pattern on
one module appears to be wrong, the YELLOW (PATTERN SET)
wire can be used to cycle forward or backward on that individual
unit until the correct pattern is selected. Note: This will only change
the pattern in the one unit and will not affect the other units
connected to the BLUE (SYNC) wire.
3. If the blue wire is unused, leave unconnected and insulated.
PULL/ROLL TAB UPWARD TO RELEASE VACUUM
FIGURE 1
ECCO Safety Group Europe
Victoria Industrial Park, Victoria Road
Seacroft, Leeds, England
www.eccosafetygroup.com
PULL/ROLL TAB
UPWARD TO
RELEASE VACUUM
LS14 2LA
+44 (0)113 2375340

Advertisement

loading

This manual is also suitable for:

Reflex 5550 seriesReflex 5545-va1Reflex 5550-va1Reflex 5545-magReflex 5550-mag