Identify a failed NVRAM module
# alerts show current
Id
Post Time
--
----------------------- -------- --------- ------- ---------------------------------
18
Wed Nov 5 18:08:53 2014 CRITICAL HWFailure Slot=NA EVT-NVRAM-00201: A hardware fault
20
Wed Nov 5 18:11:40 2014 CRITICAL Environment
enabled
# enclosure show chassis
This command may take up to a minute to complete. Please wait...
Enclosure 1
Chassis:
Chassis Part Number
Chassis Serial Number
BMC Device Revision
BMC Firmware Revision
IPMI Version
BIOS Version
BIOS Release Date
Chassis Sub-components:
Name
Product ID
---------
------------------------
IO_Board
Management Module Rev C
Mid-plane
Chassis
Figure 1 Location of NVRAM and I/O modules
1. NVRAM—slot 0
2. I/O modules—slots 1 to 11
Procedure
1. Log in as sysadmin.
2. Enter the alerts show current command for alert information about battery and
NVRAM card status or the alerts show current-detailed command for
detailed alert information about battery and NVRAM card status. The following is an
example output.
Severity
Class
3. Enter the enclosure show chassis command for detailed information about the
chassis.
100-555-009-01
NVT04135100078
1
1.60
2.0
EAPLO162
10/24/2014
Object
Message
was detected with an NVRAM card
and it may need to be replaced
EVT-NVRAM-00001: DDFS cannot be
NVRAM subsystem is not ready.
Family ID Part No.
--------- --------------- -------------- ---
000b0021
313-169-000C-00 NVT02135100110 na
002a0008
100-555-009-01
Identify a failed NVRAM module
NVRAM Module Replacement
Serial No.
Rev
NVT04135100078 na
3
Need help?
Do you have a question about the Data Domain DD9500 and is the answer not in the manual?
Questions and answers