Thermostat Wiring; Control Using 230V Mechanical Thermostats; Control Using 230V Digital Or Digital Programmable Thermostats - Immergas Inoxstor 200 Installation, Usage And Maintenance Instructions

Pre-plumbed water heater for use with audax heat pumps
Table of Contents

Advertisement

4.3

THERMOSTAT WIRING

The Audax interface board has two connectors marked TH1 and TH2 which may be used to control the Audax using a ther-
mostat, chronostat, programmer or switch.
Each of these terminals has four pins, three of which provide L, N, E, and a switched input. Applying 230V to the switched
input will activate the zone valve and turn on the audax.
Here follows three example wiring diagrams. Read and refer to the specific manufacturer's instructions for the type of
thermostat, chronostat, programmer, switch or other device used, prior to installation.

4.3.1 CONTROL USING 230V MECHANICAL THERMOSTATS

A mechanical thermostat may be used to switch 230V from the L pin of the TH1 or TH2 terminal to the SW pin.

4.3.2 CONTROL USING 230V DIGITAL OR DIGITAL PROGRAMMABLE THERMOSTATS

Where the external device requires 230V to operate, provide Live Neutral and Earth from either TH1 or TH2. The live should
be looped through the switched contact back to the SW pin on the TH1 or TH2 terminal.
Inoxstor Pre-Plumbed Water Heater
Terminal
Pin
TH1
L
TH1
N
TH1
E
TH1
SW
TH2
L
TH2
N
TH2
E
TH2
SW
Terminal
Pin
TH1
L
TH1
N
TH1
E
TH1
SW
TH2
L
TH2
N
TH2
E
TH2
SW
Installation, Usage and Maintenance Instructions
Use
To switch - Mechanical Thermostat for Zone 1
Not used
Not used
From switch - Mechanical Thermostat for Zone 1
To switch - Mechanical Thermostat for Zone 2
Not used
Not used
From switch - Mechanical Thermostat for Zone 2
Use
Power supply to Zone 1 Thermostat.
Loop onto thermostat switch input.
Power supply to Zone 1 Thermostat.
Power supply to Zone 1 Thermostat.
From switch - Mechanical Thermostat for Zone 1
Power supply to Zone 2 Thermostat.
Loop onto thermostat switch input.
Power supply to Zone 2 Thermostat.
Power supply to Zone 2 Thermostat.
From switch - Mechanical Thermostat for Zone 2