How to empty, clean and assemble the dust tank How to Separate/Clean Dust Filter Disassembling Cleaning Assembling Check before reporting the trouble 23-24 Packing List Product specifications Model: VH9001DS Voltage rating: IEC: 380W Net weight: 2.1Kg(Vacuum cleaner),1.1Kg(Station) Power cord length:5m(Vacuum cleaner), 1.5m(Station) Dimension: 254mm×340mm×170mm(Vacuum cleaner)
Product using instructions Product using instructions Use it as shown in the diagram Insert the power cord into the power If you hold the handle within 1 minute, it socket. restarts the inhaling from the bedding. When the power cord is inserted into the power socket, it makes a sound with ‘ddee~’...
Using the product Product specifications Use it as shown in the diagram Bed Mattress, Bed Cover Pillows, Cushions, etc Beddings:Mattress, Bed Cover Pillows: Large cushion, normal cushion, pillow Divide the target space to half,and The targets are narrow,so place use it pushing and pulling back and the cleaner on it and use it by pushing forth from the end.
How to Wash Inlet Disassembling Fixing Holder Bottom Plate Place a soft cloth on the floor, and flip over the main body on it.Check for foreign objects, turn the 2 fixing holders clockwise with linear shape screwdriver or similar tools and separate the bottom plate by pulling it up.Hold the roller brush and separate it by lifting it up.
How to empty, clean and assemble the dust tank How to used the product If the nap and fine dust are filled up to the empty line, it is the time to clean the filter, so empty the dust inside the dust bin, separate and clean the filter, before using it again.
How to Separate/Clean Dust Filter Disassembling Sponge Filter HEPA Filter After separating the filter from dust bin, separate sponge filter from HEPA Filter as in the figure. Cleaning Clean the filter by cleaning the HEPA filter Wash Sponge Filter in a running water, and and the gaps around the filter using the completely dry it in a shade with good brush on the dust tank or other vacuum...
Check before reporting the trouble Please check before notifying malfunction Possible Cause Possible Solution ①The inlet or dust bin is ①Remove the object with sticks, etc. Inhaling gets blocked by a big foreign ②Clean the filter weakened and object vibrating sound is ②The filters are dirty.
Page 24
Check before reporting the trouble Possible Cause Possible Solution ①Same to Malfunction 3 It only vibrates, but ①Same to Malfunction ②Clean the filter or dust bin before no inhaling 3,the suddenly power using stop cause no inhaling ③Remove the items that cause the ②Filter or dust bin is clogging badly clogged...