FAURE HERMAN 744-082 Maintenance Manual page 65

Digital flowmeter
Table of Contents

Advertisement

1.
EQUIPMENT REQUIRED
- 3 mm screwdriver.
- 30/40 W soldering iron.
- 8 and 10 mm wrenches.
- Miniature lamp extractor.
- Separator tool T5746F HARWIN.
2.
DISASSEMBLY (See IPL, figure 1)
WARNING: STANDARD WORKSHOP PRACTICES MUST BE EMPLOYED THROUGHOUT
CAUTION: THE WORK SHOULD BE CARRIED OUT IN A CLEAN DUST-FREE
CAUTION: DO NOT CAUSE DAMAGE TO THE ADJACENT COMPONENTS OR THE WIRING
A. Removing the casing
To remove casing (30), remove 4 screws (40) and 4 screws (50) and then slide the casing off
backwards.
B. Removing "Power supply" PC board (190)
- Remove 4 screws (200) and associated washers (210).
- Mark and unsolder the connecting wires from PC board (190).
C. Removing "Display" PC board (400)
- Remove 4 screws (410) and associated washers (420) and free the assembly consisting of
"Display" PC board (400) and "Logic" PC board (240) from face panel (130).
- Separate "Display" PC board (400) from "Logic" PC board (240) by removing
4 screws (280) and associated washers (290).
The document reference is online, please check the correspondence between the online documentation and the printed version.
FAURE-HERMAN
COMPONENT MAINTENANCE MANUAL
744-082 / 744-082-3
THE OPERATIONS AND PRECAUTIONS RELATING TO THE USE OF
MATERIALS AND SUBSTANCES, WHICH MAY BE INJURIOUS TO HEALTH,
MUST BE OBSERVED. PRECAUTIONS REGARDING THE HANDLING OF
ELECTROSTATIC SENSITIVE DEVICES ARE APPLICABLE.
ATMOSPHERE AND THE WORKBENCH, COMPONENTS AND TOOLS MUST BE
KEPT CLEAN.
DURING THE SOLDER WORK. DO NOT APPLY HEAT LONGER THAN
NECESSARY.
DISASSEMBLY
28-49-91
PAGE 301
JULY 17/13