Operation - Nakanishi AL -C1204 Operation Manual

Air line kit
Table of Contents

Advertisement

If the Air Filter or Regulator are damaged, all components are replacable by the end-user.
(Refer to Table 2 and Table 3).
Table 2
Name
① Air Filter
M2000 - 8 - W - S
② Regulator
R2000 - 8 - W
Table 3. Air Filter Replacing Optional
Air Filter Bowl Assy
(Polycarbonate Bowl with Manual Cock)
Air Filter Consumable Part Kit
( The set of the O-Ring, Mantle and Bowl O-Ring.)

8 . OPERATION

8 - 1 Air Filter (Fig. 2)
The water, dirt and debris are separated from the
compressed air.
The separated debris is collected in the Bowl.
8 - 2 Draining (Fig. 2)
Opening and closing the Drain Valve.
(DO NOT allow liquids and / or debris to exceed the Upper
Limit as shown in Fig. 2.)
O direction : Draining.
S direction : Stop Draining.
< To divert the drain to another location >
Connect a hose with a
by the end-user.) to the Drain Output Port and divert to
another location.
8 - 3 Regulator (Fig. 3)
< Lock and Release of the Regulator Knob >
Regulator Knob is equipped with Lock mechanism.
Release : Pull the Regulator Knob OUT to unlock.
Lock
: Push the Regulator Knob IN to the Lock
position.
< Adjusting Air Pressure >
Turn the Regulator Knob while watching Pressure Gauge
increase or decrease.
H direction : Air pressure is increased.
L direction : Air pressure is decreased.
Model
Manufacturer
Name
6mm I.D. (Not included / provided
CKD
Model
F2000 - W - BOWL
M2000 - KIT - S
Upper Limit
O : Draining
Drain Valve
Regulator Knob
L : Decrease
Lock
Release
Manufacturer
CKD
Bowl
O
S
S : Stop Draining
Drain Outlet Port
Fig. 2
Pressure Gauge
‚6
‚4
‚8
‚2
‚0
1‚0
MPa
H : Increased
L
H
Fig. 3
13

Advertisement

Table of Contents
loading