  • Page 1 エアーラインキット / Air Line Kit AL - C1204 取 扱 説 明 書 / OPERATION MANUAL 日本語:P1 - P7 / English:P9 - P15 OM-K0653 001...
  • Page 2: Cautions For Handling And Operation

    Thank you for purchasing the "AL - C1204" Air Line Kit. This Air Line Kit will supply clean and dry cooling air to the motor and spindle. THIS AIR LINE KIT IS NOT A SUBSTITUTE FOR AN AIR DRYER. Read this and all the associated component Operation Manuals carefully before use. Always keep this Operation Manual in a place where a user can referred to for reference at any time.
  • Page 3: Basic Package

    When opening the package, check if it includes all items listed in " Table. 1 Packing List Contents ". In the event of any shortage, please contact either NAKANISHI (see the " 4. CONTACT US " section) or your local dealer.
  • Page 4: Warranty

    (closed Saturday, Sunday and Public Holidays) Telephone No. : +81 (0) 289-64-3520 e-mail Address : webmaster-ie@nsk-nakanishi.co.jp 5 . FEATURES ① This Air Line Kit is designed to supply clean and dry cooling and purging air to CONTROLLER and Motor / Spindle.
  • Page 5: Specifications

    6 . SPECIFICATIONS Model AL - C1204 Primary Air Pressure Less than 1.0MPa (145psi) Secondary Air Pressure Less than 0.85MPa (123.3psi) Maximum Operation Pressure 1.0MPa (145psi) Maximum Peak Pressure Less than 1.5MPa (217.6psi) Maximum Peak Pressure at Hose Connection Less than 1.0MPa (145psi) Filtration of the Air Filter 0.3μm Primary Side Air Pressure : 0.7MPa (101.5psi)
  • Page 6: Operation

    If the Air Filter or Regulator are damaged, all components are replacable by the end-user. (Refer to Table 2 and Table 3). Table 2 Name Model Manufacturer ① Air Filter M2000 - 8 - W - S ② Regulator R2000 - 8 - W Table 3.
  • Page 7 8 - 4 ON / OFF Valve (Fig. 4) Turn the ON / OFF Lever located on the valve 90-Degrees to turn the air output ON (Open) or OFF (Close). ON (Open) Lever OFF (Close) Fig. 4 9 . INSTALLATION AND CONNECTION OF THE AIR LINE KIT CAUTION The Air Line Kit install to the horizontal.
  • Page 8: 10 . Troubleshooting

    9 - 2 Connection of the Air Line Kit (1) Connect the 6.0mm Air Hose to the Primary Joint. (2) Connect the 6mm air hose to the Secondary Joint to the Air Input Quick Disconnect on the front of the CONTROLLER.