When you have this problem...
The handset won't display any
Caller ID information.
The handset is not working.
The handset says "Unavailable".
The Voice Message Waiting
Indicator does not work.

8-2. Re-registering the Handset

When you first put your handset into the base, it is registered so it can communicate with the base. There may
be some times when you have to re-register your handset to the base:
When you want to change the handset-to-base code.
When there is a power failure that lasts more than one hour.
If the handset's battery is completely discharged. (The handset must be recharged for 15 - 20 hours before
re-registering to the base.)
Any time you experience difficulty connecting to the base to make or receive calls.
To re-register the handset:
Pick up the handset from the base. Press and hold [find hs] on the base.
1)
While holding [find hs], place the handset in the base. The charge/in use LED on the base begins to flash,
2)
indicating the base is registering the handset. Wait for at least five seconds.
3)
Pick up the handset from the base and press [TALK/flash]. If the display shows TALK, the handset is
registered. If not, place the handset in the base to try again.
Press [END].
4)
8-3. Changing the Handset-to-base Code
The handset-to-base code prevents other cordless devices from accidentally connecting to your base. If the
battery pack is completely discharged or removed, the handset-to-base code will be lost. If this happens, a new
code is set automatically the next time the handset is charged in the base. In the rare situation that you suspect
another cordless telephone is using the same code, you can change the code.
To change the handset-to-base code, re-register the handset to the base following the instructions in section
8-2 on Re-registering the Handset above.

8-4. Traveling Out of Range

During a call, as you begin to move your handset too far from your base, noise increases. If you pass the range
limits of the base, your call will terminate within one minute.

8-5. Liquid Damage

Moisture and liquid can damage your cordless phone.
If the handset or base is exposed to moisture or liquid, but only the exterior plastic housing is affected, wipe
off the liquid, and use as normal.
If moisture or liquid has entered the plastic housing (i.e. liquid can be heard in the phone or liquid has entered
the handset battery compartment or vent openings on the base), follow the steps below:
1)
Remove the battery cover and leave it off for ventilation.
2)
Disconnect the battery pack. Leave the battery cover off and the
battery pack disconnected for at least three days.
3)
Once the handset is completely dry, reconnect the battery pack and
the battery cover.
4)
Recharge the handset's battery pack for 15 to 20 hours before using.
IMPORTANT:
You must unplug the telephone line while recharging the battery pack to avoid charge interruption.
CAUTION!
DO NOT use a microwave oven to speed up the drying process. This will cause permanent damage to the
handset, base and the microwave oven. After following these steps, if your cordless telephone does not work,
please call our Customer Service Hotline. See back cover page for contact information.

8-6. Specifications

The phone complies with FCC Parts 15 and 68.
Operating temperature 0°C to +50°C (+32°F to +122°F)
AC Adapter
Battery
Frequency
Note: To avoid damage to the phone, use only Uniden PS-0008 and BT-905 with your phone.
Specifications, features, and availability of optional accessories are all subject to change without prior notice.

8-7. Power Failure Operation

During the period that the power is off, you will not be able to make or receive calls with the telephone.

8-8. Battery Information

Average battery life
With average use, your handset battery provides approximately six hours of talk time and approximately
fourteen days of standby time. You can achieve optimum battery life and performance by returning the handset
to the cradle after each use. When your handset is left off of the cradle, the battery will gradually discharge
even if the handset is not being used. The actual talk time duration will be reduced in proportion to the amount
of time the handset is off the cradle.
Letting incoming calls ring at least twice before answering.
Checking to see if the call was placed through a switchboard.
Checking with your telephone service provider to make sure your
Caller ID service is active (See section 5).
Checking the battery pack connection.
Charging the battery for 15-20 hours.
Changing the handset-to-base code (See section 8-3).
Moving the handset closer to the base.
Making sure the base is plugged in.
Changing the handset-to-base code (See section 8-3).
Contact your local telephone company to make sure that your
telephone receives FSK message signaling.
Reset the indicator by pressing and holding [find hs] for five seconds.
Handset
Part number
Input Voltage
Output Voltage
Part number
Capacity
921.103102 – 923.787761 MHz
5,856.533347 – 5,863.692437MHz
Try...
1)
2)
3)
PS-0008
120V AC 60Hz
9V DC 210mA
BT-905
600mAh, 3.6V
Base
Disconnect the AC adapter
from the base, cutting off
electrical power.
Disconnect the telephone cord
from the base.
Let dry for at least three days.

Hide quick links: