WATER SUPPLY CONNECTION
5. With the steel clamp and screw,
secure the water supply line (copper
tubing only) to the rear panel of
refrigerator as shown.
6. Coil the excess water supply line
(copper tubing only), about 2½ turns,
behind refrigerator as shown and
arrange coils so they do not vibrate or
wear against any other surface.
7.
Turn ON the water supply at shutoff
valve and tighten any connections
that leak.
8. Reconnect the appliance to electri-
cal power source.
NOTE
Check with your local building authori-
ty for recommendations on water lines
and associated materials prior to in-
stalling your new refrigerator. Depend-
ing on your local/state building codes,
Frigidaire recommends for homes with
existing valves its Smart Choice® water
line kit 5305513409 (with a 6�Stain-
less Steel Water Line) and for homes
without an existing valve, Frigidaire
recommends its Smart Choice® water
line kit 5305510264 (with a 20�copper
water line with self-tapping saddle
valve). Please refer to Frigidaire.com for
more information.