MOBY Commands
GET: Read UIDs of all MDSs (MOBY U) (see chapter 4.2.14)
This command is extremely important if you are using more than one MDS in the
field. It provides the UIDs (unique identifiers) of all MDSs currently present in the
field. One of the UIDs supplied here must then be copied to the applicable MDS
command (e.g., READ, WRITE). UDT 200 (MOBY UID4) is available for the GET
data for easy handling of the UID.
The GET command is always executed when bit ANZ_presence_change = 1
indicates that the configuration of the MDS in the field has changed (see
chapters 3.3 and 5.7).
SET-ANT: Turn antenna of the SLG on or off (see chapter 4.2.17)
This command is not needed during normal operation since the antenna is always
on after an SLG is turned on.
The antenna must be turned off when two sensitive SLGs are to be located very
close to each other. The application software must ensure that only one antenna is
on at once.
ASM/SLG-STATUS: Read information about the operating status of the ASM and
Reads ASM specific data in DAT_DB_number/DAT_DB_address.
(System command; no dialog takes place with the MDS).
4-6
SLG (see chapter 4.2.16)
FC 56
J31069-D0155-U001-A0-7618