Siemens MOBY FC 56 Technical Description page 115

Table of Contents

Advertisement

Input parameters for ASM 475
Assignment takes place in UDT 10 (see chapter 3).
Table A-1
Input parameters for ASM 475
Address
Name
+0.0
ASM_address
+2.0
ASM_channel
+8.0
MDS_IO_control
+9.0
ECC_mode
+9.2
priority_RW
+9.3
priority_RWD
+10.0
MOBY_mode
+11.0
scanning_time
+12.0
SLG_number
+14.0
distance_limiting
+15.0
multitag
+16.0
field_ON_control
+17.0
field_ON_time
Command table of the ASM 475
The ASM 475 processes all the commands described in chapter 4.
FC 56
J31069-D0155-U001-A0-7618
Short Description of the ASM Hardware
Permissible Values
256, 272, 288 ... 752
Centralized layout:
Addresses are specified by HW Config
(see chapter 2.5).
0, 4, 8, ...
Distributed layout:
Automatic or manual address assign-
ment
1, 2
2 parallel channels
B#16#0, 1, 4, 5
Enable/disable presence check
TRUE, FALSE
TRUE is only permitted when
MOBY_mode is parameterized with 1.
TRUE, FALSE
(see chapter 3.1)
TRUE, FALSE
(see chapter 3.1)
B#16#1, 5, 6
MOBY I/U
B#16#00 ... FF
A value other than 00 is only recom-
mended when MOBY_mode was
parameterized appropriately (see
chapter 3.1)
B#16#0001 ... FFFF
The test function is on for FFFF (see
chapter 3.1).
B#16#05, 0A, 0F, 14,
19, 1E, 23
B#16#1
B#16#0, 1, 2
B#16#00 ... FF
Commentary
A-3