Download Print this page

Caple BUCH Instruction Manual page 7

Built under extractor

Advertisement

I N S T A L L A T I O N
M O U N T I N G T H E E X T R A C T O R
Fit the ducting adaptor to the cooker hood using the short screws supplied. Create an opening of
492mm x 260mm in the underside of the cupboard where the hood will be installed.
Remove the face plate by removing the two visible screws located on both sides. Eight mounting
holes around the unit are accessible.
Lift the cooker hood and place into opening the cupboard. Secure the unit using the long screws
supplied and then refit the face plate.
12
Instruction manual BUCH
Please keep this instruction manual for future reference
O P E R A T I N G I N S T R U C T I O N S
C O N T R O L S
L I G H T:
The light can be operated independently by sliding the light switch on/off despite the working
status of the fan. Please refer to the icon switch panel.
FA N :
The fan is operated by sliding the power switch on. It can be run at three different speeds (Speed
1/Speed 2/Speed 3) depending on the cooking requirements. Please refer to the icon on the switch
panel.
C L E A N I N G A N D M A I N T E N A N C E :
Switch off the extractor before cleaning or maintenance. To prevent surface damage never use
abrasive or oil based liquid cleaners. To clean the surfaces of the appliance, use mild detergent and
warm water. In areas of high humidity and coastal environments cleaning should be carried
out frequently.
W A R N I N G :
A build up of oil may occur if the extractor is not cleaned regularly.
F I LT E R M A I N T E N A N C E :
To maintain efficiency, the filters should be removed regularly (approximately monthly), and
washed using hot soapy water of the dishwasher.
N OT E :
Some discolouration of the frame may occur if washed in the dishwasher.
Extractors fitted with charcoal filters are designed to remove grease and odours from cooking
vapours prior to the cleansed air re-entering the kitchen (when the extractor is in recirculation
mode). Charcoal filters should be replaced every 6 months, these can be ordered from
www.caple.co.uk (code CAP73CF).
N OT E :
Fully saturated charcoal filters can become a barrier to air movement therefore limiting extractor
performance. In the event of fire, grease laden filters could be flammable and therefore require
replacement is recommended.
Please keep this instruction manual for future reference
Instruction manual BUCH
13

Advertisement