Troubleshooting Guide - U-Line 2275DWRWOL Use And Care Manual

Echelon series
Hide thumbs Also See for 2275DWRWOL:
Table of Contents

Advertisement

Troubleshooting Guide

DANGER
ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.
Troubleshooting - What to check when problems occur:
PROBLEM
Unit does not operate and
electronic display is blank.
No interior light
Unit not cold enough. Check
temperatures (See OPERATION for
approximate temperatures).
Unit is too cold. Check temperatures
(See OPERATION for approximate
temperatures).
The unit frosts up.
Noise during operation.
Drawer(s) can't close.
22
POSSIBLE CAUSE
No electrical supply
Loose or burned out bulb
Control set too warm
Airflow to front grille blocked
Dirty condenser coils
Door gasket not sealing properly
Item(s) interfering with drawer
Inaccurate temperature reading
Control set too cold
High ambient temperatures or
humidity
Certain sounds are normal.
Item(s) interfering with drawer
Unit not level
2275DWRWS, 2275DWRWOL
REMEDY
Plug unit in or check circuit breaker.
Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).
Set control to a cooler setting (See OPERATION). Allow
24 hours for temperature to stabilize.
Airflow must not be obstructed to front grille (See
OPERATION).
Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).
Door adjustment required (See MAINTENANCE; ADJUST
DRAWERS).
Reposition or remove item(s).
Properly check temperature (See OPERATION).
Set control to a warmer setting (See OPERATION). Allow
24 hours for temperature to stabilize.
Defrost unit manually (See MAINTENANCE;
DEFROSTING).
Soft sounds from the fan and water/dropping sounds
from the ice maker will be heard.
Adjust items in drawer(s).
Make sure unit is level (See LEVELING, page 14).