Do not use this equipment in a hazardous atmosphere or with hazardous materials for which the equipment was not designed. New Brunswick Scientific Co., Inc. (NBS) is not responsible for any damage to this equipment that may result from the use of an accessory not manufactured by NBS.
Page 7
Reproduction, adaptation, or translation without prior written permission from New Brunswick Scientific is prohibited. Disclaimer Notice New Brunswick Scientific Co., Inc. reserves the right to change information in this document without notice. Updates to information in this document reflect our commitment to continuing product development and improvement.
Page 9
W A R R A N T Y Every Instrument manufactured by the New Brunswick Scientific Co., Inc. is warranted to be free from defects in material and work- manship. This apparatus with the exception of glassware, lamps and electrodes (where supplied), is warranted for 1 year against faulty com-...
The Innova 2000/2050 Digital Platform Shaker will provide you with reliable and maintenance-free operation that is characteristic of all NBS shakers. The Innova 2000/2050 incorporates a variety of state-of-the-art components and features to permit the precision operation necessary for your exacting scientific experiments.
Page 14
THIS PAGE IS INTENTIONALLY BLANK M1190-0050 Innova 2000/2050 User’s Guide...
• Deviations of shaking speed or temperature outside of tolerance limits A wide variety of platforms can be used with the Innova 2000/2050. Dedicated platforms are available for a variety of flask sizes. Universal platforms, utility trays and utility carriers are also available (see Section 7 for accessories).
There are four function indicator and four status indicator lights on the control panel as well. A general description of the display, user interface keys and indicators follows. For operation of the control panel, see Section 5, Operation. M1190-0050 Innova 2000/2050 User’s Guide...
• Setpoints • Hours remaining (timed run) • Measured temperature (when Temperature Monitor option is installed) 2.2.2 User Interface Keys There are four user interface keys on the control panel. Table 1 below explains their functions: New Brunswick Scientific User’s Guide...
Function Revolutions Per Minute shaking speed Hours: run time remaining ºC Temperature in degrees Celsius (activated only if the optional Temperature Monitor is installed) This function is not active in the Innova 2000 or 2050 M1190-0050 Innova 2000/2050 User’s Guide...
(see Section 4.3 for installation instructions). The Innova 2000 can be used with a wide range of NBS 11” x 13” (28 cm x 33 cm) platforms, which will accept a variety of clamps for flasks, test tubes, etc. For details, see the listing in Section 7.1.
• Control of analog power supplies; • Signal conditioning of RTD sensor readings; • Provide remote monitoring capabilities by supplying analog outputs for speed and temperature that are compatible with chart recorders and analog data acquisition systems. M1190-0050 Innova 2000/2050 User’s Guide...
It is possible to significantly increase the capacity of an Innova 2000 shaker with an available capacity upgrade package (NBS part number M1190-9910). This option will simply and easily convert an Innova 2000 to an Innova 2050. This package consists of a 12” x 16” (30.5 cm x 40.6 cm) subplatform to replace the 11”...
Page 22
THIS PAGE IS INTENTIONALLY BLANK M1190-0050 Innova 2000/2050 User’s Guide...
11” x 13” (28cm x 33 cm) platforms used on the NBS model G2 Shaker can also be used on the Innova 2000. If you have an Innova 2050 or a 2000 with the capacity upgrade package, you will need a 12” x 16” (30.5 cm x 40.6 cm) platform.
Page 24
THIS PAGE IS INTENTIONALLY BLANK M1190-0050 Innova 2000/2050 User’s Guide...
43 cm Innova 2050 17 inches 14¼ inches 5⅜ inches 20 inches 20 inches 43 cm 36 cm 13.9 cm 50 cm 50 cm Figure 4a: Innova 2000 Operating Space Figure 4b: Innova 2050 Operating Space New Brunswick Scientific User’s Guide...
Because NBS flask clamps are used on a variety of shaker platforms, flat head screws of different lengths and thread pitch are used to secure the clamp, according to the platform. The following tables will help you identify the proper screw for your shaker application: M1190-0050 Innova 2000/2050 User’s Guide...
Page 27
(making sure they are the correct type of screws by referring to Tables 6 & 7 above). 2. Place the loose girdle around the upper portion of clamp body so that it is held in place by the legs of the clamp. 3. Insert the flask into the clamp. New Brunswick Scientific User’s Guide...
Page 28
Figure 5: 2- to 6-Liter Clamp Installation CLAMP UPPER GIRDLE MOUNTING WITH GIRDLE HOLES (5) TUBES PLATFORM CLAMP BODY LOWER (LEGS AND BASE) GIRDLE WITH GIRDLE TUBES NOTE: Figure 5 is also valid for 2800 ml Fernbach Flask Clamps. M1190-0050 Innova 2000/2050 User’s Guide...
2. Press either to enter the mode and display the current setpoint. CAUTION! Holding the key for more than 0.5 second will cause the speed setpoint to change. Should this occur, resetting will be necessary. New Brunswick Scientific User’s Guide...
Alarm Functions Innova shakers have an audible alarm which is activated at predetermined times. To deactivate the alarm: 1. Press until the indicator is illuminated. SELECT 2. Simultaneously press the keys. The indicators will MAINT flash. M1190-0050 Innova 2000/2050 User’s Guide...
MUTE that the alarm has been reactivated. Total Running Time To track hours of usage, the Innova 2000/2050 control modules total the time the shaker has been . To display the accumulated running time: 1. Select using the key.
Do not use abrasive or corrosive compounds to clean this instrument, as they may damage the unit and void the warranty. The Innova 2000/2050 requires no routine maintenance by the user. The MAINT indicator light goes on at the end of 10,000 hours of use.
2. Using a small screwdriver, remove the cover/fuse block located on the rear panel. 3. Remove the old fuse, insert a new one of the same type, and replace the cover/fuse block into the power module. Figure 6: Power Module/Fuse Block New Brunswick Scientific User’s Guide...
8. Check for the correct fusing arrangement (see Section 6.3). NOTE: Be sure the indicator pin is facing out and the alignment arrow is pointing to the left. 9. Replace the cover/fuse block assembly. 10. Verify that the indicator pin shows the desired voltage. M1190-0050 Innova 2000/2050 User’s Guide...
Single to Double Fuse Conversion 1. Open the cover of the power module using a small blade screwdriver and remove the cover/fuse block assembly (see Figure 6, repeated below for easy reference). Figure 6: Power Module/Fuse Block New Brunswick Scientific User’s Guide...
Page 36
4. Invert the fuse block and slide it back onto the Phillips screw and pedestal. Tighten the Phillips screw. 5. Verify the correct fusing arrangement (see Figures 10a and 10b). 6. Replace the cover onto the power module. Figure 10a: Double Fuse Arrangement Figure 10b: Single Fuse Arrangement M1190-0050 Innova 2000/2050 User’s Guide...
2. Remove the foam pad. 3. Remove the nine screws that hold the subplatform in place: three screws around each of the bearings. 4. Lift the upper housing straight up and clear the bearing retainers. Figure 11: Subplatform Cutaway New Brunswick Scientific User’s Guide...
2. Move the motor assembly until the belt is tight. 3. Tighten the hex nuts and recheck the belt tension by exerting pressure on the belt. The belt should deflect approximately 3/8 inch (9.5 mm). 4. Reinstall the subplatform (see Section6.6 below). M1190-0050 Innova 2000/2050 User’s Guide...
6. Replace the foam pad and platform, and reconnect the power cord. The unit is now ready for operation. Replacing the Motor Assembly 1. Remove the platform and subplatform (see Section 6.4). 2. Remove the two hex nuts and washers that retain the motor mounting plate (see Figure 14). New Brunswick Scientific User’s Guide...
A regular schedule of routine maintenance is an excellent way to keep your valuable equipment performing optimally for years of reliable service. M1190-0050 Innova 2000/2050 User’s Guide...
Temperature Monitor Option The Temperature Monitor option package (NBS part number M1190-9909) is available for both Innova 2000 and 2050 models. When installed, this option provides: • Digital Temperature Readout The temperature of the liquid in any vessel or the ambient temperature may be monitored with an RTD-based electronic device and the value shown on the shaker’s LED display.
6. Screw on the three hex spacers (P0160-2273, provided in the kit) in positions A, B and C. 7. Align the mating connector on the temperature module PC board with the option connector on the main control board and press down until the connector is seated. M1190-0050 Innova 2000/2050 User’s Guide...
12 x 16-inch (30.5 x 40.6 cm) platforms. The platform, however, much be purchased separately. Before scheduling the Service Engineer for field installation, it is a good idea to confirm against the packing list that you have received all the parts. New Brunswick Scientific User’s Guide...
6. Insert the new 12 x 16-inch (30.5 x 40.6 cm) foam pad into the subplatform and install a 12 x 16-inch (30.5 x 40.6 cm) platform. Be sure to secure the platform with the thumb screws. M1190-0050 Innova 2000/2050 User’s Guide...
& & Innova 2000 Platforms Number Description Part Number of Clamps (11 x 13 in. / 28 x 33 cm Platform) AG2-UT Utility Carrier AG2-00 Utilility Tray M1001-0240 Universal Platform AG2-10 for 10ml Erlenmeyer flasks AG2-25 for 25ml Erlenmeyer flasks...
500 ml Media Bottles ACSB-1000S for 1-liter Media Bottles All above clamps constructed of stainless steel. Service Parts Model NBS Part Number Description Quantity Innova 2000 & 2050 P0380-3830 0.200A Fuse P0380-3410 1.0A 5x20 mm Fuse EF-104 1.0A 3AG Fuse P0420-1610 10VA Transformer...
Innova 2000 Shaker SHAKING Speed 25-500 rpm ± 1 rpm (see NOTE below) Control Accuracy Indication 3-Digit LED, in 1 rpm increments Stroke/Orbit ¾-inch (1.9 cm) Setpoint & Control Digital adjustment with PI microprocessor control and instantaneous visual feedback. OPERATING AMBIENT 0º...
Page 48
NOTE: The Innova 2000 can be upgraded to a larger capacity platform with a kit that converts this shaker to an Innova 2050. This kit can be installed in the field. Innova 2050 Shaker SHAKING 25-500 rpm Speed ± 1 rpm (see NOTE below)
Page 49
At 25-400 RPM, the unit will perform to specifications with up to ± 10% line voltage fluctuation. To attain speed accuracy at 401-500 RPM, the line voltage cannot be lower than 5% of the rated voltage. New Brunswick Scientific User’s Guide...
Page 50
THIS PAGE IS INTENTIONALLY BLANK M1190-0050 Innova 2000/2050 User’s Guide...
Description Page Front View Rear View Control Panel Counterbalanced Drive Mechanism Innova 2000 Operating Space Innova 2050 Operating Space 2- to 6-Liter Clamp Installation Power Module/Fuse Block 33,35 Voltage Selector Card Orientation Voltage Selector Card Indicator Pin & Alignment Arrow...
Need help?
Do you have a question about the Innova 2000 and is the answer not in the manual?
Questions and answers