Liability Notice Condair Ltd. does not accept any liability due to incorrect installation, maintenance or operation of the equipment, or due to the use of parts/components/equipment that are not authorized by Condair Ltd. Copyright Notice Copyright 2020, Condair Ltd., All rights reserved.
Thank you for purchasing the Condair HumiLife RE. The Condair HumiLife RE incorporates the latest technical advances and meets recognized safety standards. Improper use of the Condair HumiLife RE may result in danger to the user or third parties, and/or damage to property.
Disconnect power before any servicing. Electrical compartment contains low voltage components. Condair does not accept any liability for installations of humidity equipment installed by unqualified personnel, or the use of parts, components, or equipment that are not authorized or approved by Condair.
Page 5
Preventing Unsafe Operation All personnel working with the Condair HumiLife RE must immediately report to the customer any alterations or changes to the unit that may affect safety, and secure the unit against accidental power-up. If it is suspected that the unit cannot be operated safely for any of the reasons listed below, shut it down immediately.
Page 6
Once the humidifier is mounted, and water, drain, and wiring connections have been established, you can turn on the unit and control it with the Condair HumiLife app on your mobile device. If the humidifier installation has not yet been completed, please refer to the installation manual to finalize the installation before proceeding.
Alerts If there is an issue with the humidifier, the Alert light will turn on and an alert will appear in the Condair Humilife app. For a yellow light, refer to the app or the Operation manual. A red light indicates an error.
Page 8
Deactivating will put the unit on standby Opens the menu Go to home screen * Absence of slider indicates an installed external humidity controller. Change the settings on the controller to change the setpoint. Understanding the Main Page | 8 Condair RE...
After removing power from the humidifier, close the water supply valve. Changing the Setpoint Changing the setpoint of your HumiLife humidifier requires the Condair HumiLife app. The ideal indoor humidity range is between 40% and 60%. To reach a particular humidity level, a setpoint (or desired humidity) is determined for the humidifier.
5. Remove the ceramic media. The ceramic media can now be cleaned or replaced. 6. Push the ceramic media into the unit and secure with the tabs. Restore the water connection. 7. Reinstall the cover, then reset the maintenance timer in the Condair HumiLife app. Maintenance | 10...
Page 11
3. (Recommended) Wipe down the inside of the humidifier, especially near the base where the ceramic media sits. 4. Return the ceramic media to the humidifier, reattach the water hose to the ceramic media, and reinstall the covers. Condair RE Maintenance | 11...
Electrical repairs must only be performed by a licensed electrician authorized by the customer, or by Condair service technicians. Troubleshooting the Condair HumiLife RE may require the user to access the inside of the unit, to the control and plumbing cabinets, which may expose the user and equipment to hazards described in "For...
Page 13
A fuse inside the humidifier has blown. Connect the humidifier to the power supply. Plug in the humidifier to the wall outlet. If the fuse on the humidifier control board is blown, contact Condair to check the unit. Condair RE...
5 seconds to enter AP mode. Use your phone The WiFi from the to connect to the humidifier. Use the Condair HumiLife app to connect the humidifier to light is red internet. the internet by using your home network ID and password.
Page 15
The ceramic media has approached the end of its life and must be replaced. media needs After replacement, reset the system error by pressing and holding the power button for The media to be 3 seconds. and alert replaced. light is red Condair RE Troubleshooting | 15...
Page 16
Check if there is warm air flowing through the duct. If the air is too cold, there is a chance condensate will form in the duct, allowing mold to form. Ensure the furnace is on. Humidity in the air duct is too high. 16 | Troubleshooting Condair RE...
All water supply and drain line connections must be installed in accordance with local plumbing codes by a licensed plumber. Condair does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts/components/equipment that are not authorized or approved by Condair.