Page 2
PWRguard PLUS. The PWRguard PLUS also has a piezo buzzer alarm which will sound once per minute during load disconnect. This alarm can be disabled if you do not need an audible alert.
The piezo buzzer alarm can be disabled by removing the jumper from the terminal post marked “Buzzer”. 4. When the power supply is switched on, the PWRguard Plus unit will become operational and the AUTO RESET and ON LEDs will both glow green.
Page 4
RIGrunner input terminal. This will provide protection for the battery and all the devices that are plugged into the RIGrunner. Additionally, after loss of AC mains power, the PWRguard PLUS will reset the system after the power is restored.
Fuse The PWRguard PLUS fuse is used to protect the source and the load from excessive current. The PWRguard PLUS includes a 40A fuse (the rating of the PWRguard PLUS.) The fuse may be changed to a lower value if desired for protection of other system components downstream.
Page 6
GREEN LED – light showing that the output is ON. The small LED, Output ON being off, indicates the PWRguard PLUS is in Manual Reset Mode. The RED LED (Hi-Fault) will light whenever the input voltage exceeds 15.0V. The GREEN LED will go OFF and there will be NO output voltage.
Page 7
(lower right) or to just run it when needed. Open the PWRguard Plus unit and power it up. When the LED is on, connect a micro-USB cable (not included with unit) between the PWRguard Plus and the PC.
After the driver is found, start the West Mountain Radio diagnostics utility program. Find the PWRguard Plus in the list of devices. Right-click on the PWRguard Plus and select “TEST”. When the terminal window pops up, press enter in the terminal area and the following menu will appear: West Mountain Radio PWRguard+ 1.14...
Repaired or replaced items are warranted for the remainder of the original warranty period. You will be charged for repair or replacement of the PWRguard Plus or accessory made after the expiration of the warranty period.
Need help?
Do you have a question about the PWRguard PLUS and is the answer not in the manual?