Electrical Instructions - True Milk Coolers TMC-58-S Installation Manual

Tmc units (milk coolers)
Hide thumbs Also See for Milk Coolers TMC-58-S:
Table of Contents

Advertisement

LEVELING CASTORS CONTINUED....
Install the desired number of shims (in pairs as shown
in figure 3), making sure the slots in the shim are in
contact with the castor mounting bolts.
Tighten and secure the shims and castor(s).
Repeat process until cabinet is level.
D. Ensure that the drain hose or hoses are positioned in
the pan.
Image 3

ELECTRICAL INSTRUCTIONS

A. Before your new unit is connected to a power
supply, check the incoming voltage with a
voltmeter. If anything less than 100% of the rated
voltage for operation is noted, correct immediately.
B. All units are equipped with a 9 ft. (2.7m) service
cord, and must be powered at proper operating
voltage at all times. Refer to cabinet data plate for
this voltage.
TRUE requires that a sole use circuit be dedicated for
the unit. Failure to do so voids warranty.
6
INSTALLATION / OPERATION INSTRUCTIONS
............ www.truemfg.com ............
True Food Service Equipment, Inc.
Image 2
CAUTION
Voltage drops can occur due to long wire runs from the voltage
source. Consult the wiring chart on page 7 to insure proper
voltage.
WARNING
Compressor warranties are void if compressor burns out due to
low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove lower rear grill, wiring
diagram is positioned inside on the ballast box.