Direct draw beer dispenser: solid door club top (2 pages)
Summary of Contents for True TWC-24-OP
Page 1
WINE AND BEVERAGE CABINET USE AND CARE MANUAL Use and Care ManUal / installation instrUCtions tWC, tbC, tUr Models (all overlay models - oP/oPg included) Wine Cabinets, beverage Centers and UnderCoUnter refrigerators www.true-residential.com...
“just a few days”. If you are getting rid of your old refrigerator, please follow the instructions below to help prevent Before you start to install your True unit, carefully inspect it for accidents. freight damage. If damage is discovered, immediately file a Before you throw away your old refrigerator or freezer: claim with the delivery freight carrier.
WINE AND BEVERAGE CABINET USE AND CARE MANUAL U N C R A T I N G C A B I N E T C L E A N I N G Tools Required: A. The exterior may be wiped clean with mild soap and water. •...
(ground) prong from the power cord. For personal safety, this appliance must be properly grounded. B. Proper leveling of your True refrigerator is critical to operating success (for non-mobile models). Effective condensate removal Before your new unit is connected to a power supply, check the and door operation will be effected by leveling.
WINE AND BEVERAGE CABINET USE AND CARE MANUAL 938786 I N S T A L L I N G A N T I - T I P B R A C K E T S R E Q U I R E D F O R S T A C K E D A N D D R A W E R U N I T S Tip Over Hazard: A child or adult can tip the refrigerator and may cause property or bodily harm.
OPENING installing any models. DEPTH 25" True’s Wine Cabinets and Beverage Center are designed to be inserted into a cabinet opening or free standing. When installing the Wine Cabinet or Beverage Center into a rough ROUGH OPENING opening make sure there is a properly prepared opening for door WIDTH swing clearance and electrical placement.
Page 9
WINE AND BEVERAGE CABINET USE AND CARE MANUAL OVERLAY ( OP / OP G) INSTAL L AT I ON DRAW E RE D MO DE LS ROUGH ROUGH OPENING OPENING DEPTH HEIGHT 25" Min 34 ” - Max 35” ROUGH OPENING WIDTH 24"...
Page 10
IN STAL L IN G OV E R LAY MODEL S FOR GLASS D OOR True’s Overlay Models are designed to be inserted into a & S O LI D DO O R M ODELS cabinet opening or free standing.
Page 11
WINE AND BEVERAGE CABINET USE AND CARE MANUAL OV E RL AY (O P /O P G) INSTALLATION IN STAL L IN G OV E R LAY MODELS FOR DRAWE R E D MODELS " " " .965" " (top, left, right) "...
Page 12
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N G O V E R L AY PA N E L S F O R G L A S S D O O R & S O L I D D O O R M O D E L S Tools Needed: •...
Page 13
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N G O V E R L AY PA N E L S F O R G L A S S D O O R & S O L I D D O O R M O D E L S , C O N T I N U E D 7) There are pre-marked areas on the front of the door.
Page 14
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N G O V E R L AY PA N E L S F O R D R A W E R E D M O D E L S Tools Needed: •...
Page 15
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N G O V E R L AY PA N E L S F O R D R A W E R E D M O D E L S , C O N T I N U E D 6) Secure overlay panel to drawer panel using appropriate size screws.
• Floor protector Stacking Brackets Image 1. True Signature Louver Grill Kit 1) Lay floor protectant down. 2) Uncrate cabinets and secure both shelving and doors/drawers. 3) Install the anti-tip device per its instructions. (See page 5). 4) Trial fit anti-tip brackets using the lower cabinet.
Page 17
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N G T R U E S I G N A T U R E I N S T A L L I N G A N T I - T I P B R A C K E T S L O U V E R G R I L L , C O N T I N U E D R E Q U I R E D F O R S T A C K E D A N D D R A W E R U N I T S...
C. TBC & TUR models are set from the factory at 35˚F. D. Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace the temperature control, be sure it is ordered from your True dealer or authorized service agent. RECOMMENDATION Before loading product, we recommend running your True unit empty for 24 hours.
D R A W E R D I V I D E R I N S T A L L A T I O N A N D O P E R A T I O N A. The True Professional TUR-24D (Drawer Unit) comes with clear drawer dividers. (See image 7).
R E P L A C E M E N T P A R T S A. Keeping the condenser coil clean will minimize required True maintains a record of the cabinet serial number for your service and lower electrical cost. The condenser coil is cooler.
I N S T A L L A T I O N S P E C I F I C A T I O N S ” True’s Wine Cabinets and Beverage Cabinets are designed to be Please go to page 5 for overlay dimensions before installing...
I N S T A L L A T I O N S P E C I F I C A T I O N S WARNING: These dimensions are for TUR-24 Drawer models only! True’s TUR-24 Drawer units are designed to be inserted into a cabinet opening or free standing. When installing the TUR-24 Drawer unit into a rough opening, make sure there is a properly prepared opening for drawer opening clearance and electrical placement.
WINE AND BEVERAGE CABINET USE AND CARE MANUAL T A P P E R U N I T I N S T A L L A T I O N U N D E R M A T E R I A L R E Q U I R E D : C O U N T E R T O P S •...
WINE AND BEVERAGE CABINET USE AND CARE MANUAL I N S T A L L I N g D R A f T S T A N D A R D A N D H O O K U P Required Tools and Parts •...
Page 26
WINE AND BEVERAGE CABINET USE AND CARE MANUAL Figure 5 Figure 8 Beer hose Connection Figure 6 Step 5 Figure 9 remove the cap and run the air hose to the top of the draft standard. hook the hose onto the stainless Step 8 tube to keep hose from falling out (this hose will keep Place Co...
WINE AND BEVERAGE CABINET USE AND CARE MANUAL PRESSURE Dispensing pressures differ according to: • The type of draft dispensing system Helpful Hints On Maintaining The Correct Pressure: • The length of draft dispensing line • Know which pressurizing agent to use on which product and why. • The actual product - some require more, some require less • Monitor your regulators to ensure applied pressure remains constant • The temperature of the product • Keep equipment in good repair • The pressurizing agent: air pressure, or special blended gases. TAPPINg do not agitate the kegs unnecessarily. If excessive agitation Prior to tapping the keg, ensure that all beer faucet in the serving occurs allow kegs to settle for 1 to 2 hours before tapping.
WINE AND BEVERAGE CABINET USE AND CARE MANUAL CHANgINg CO gAS CYLINDER follow these instructions at ALL times when you replace a CO gas cylinder: Close cylinder at "A". remove tap "d" from barrel. Pull pressure release ring on body of tap to release pressure remaining in line.
If you are using the cleaning kit keg. purchased from true follow these instructions: Draw the water from the beer line; now you’re ready to serve brewery fresh, golden beer.
This will disappear once the humidity levels drop. Service is required. • Check the model and serial number, located on the interior top of the unit, behind the LED lighting. Call your dealer or True service department at 1-800-325-6152, or email at trueprofessional@truemfg.com.
WINE AND BEVERAGE CABINET USE AND CARE MANUAL F R E Q U E N T L Y A S K E D Q U E S T I O N S Q. How do I adjust the temperature? A. Refer to the page 15 – Startup/Temperature Control instructions. Q.
CAUTION: Do not use any steel wool, abrasive or chlorine based products to clean stainless steel surfaces. Please ensure that you use appropriate products when cleaning and polishing your True equipment. Cleaners containing chlorine must not be used as these will attack the stainless steel causing damage and in some cases corrosion.
W A R R A N T Y C L A I M S All claims for labor or parts must be made directly through TRUE. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect.
Page 34
WINE AND BEVERAGE CABINET USE AND CARE MANUAL NOTES:...
Page 35
WINE AND BEVERAGE CABINET USE AND CARE MANUAL...
Page 36
Wine Cabinets, beverage Centers and UnderCoUnter refrigerators Use and Care ManUal / installation instrUCtions www.true-residential.com 2001 East Terra Lane • O’Fallon, Missouri 63366-4434 USA Tel: (636) 240-2400 • Toll Free: (888) 616-8783 • Parts: (800) 424-8783 Fax: (636) 272-7546 • E-mail: trueprofessional @ truemfg.com...
Need help?
Do you have a question about the TWC-24-OP and is the answer not in the manual?
Questions and answers