Disclaimer The content of this manual is for informational use only and is subject to change without notice. Focal Meditech BV assumes no responsibility or liability for any errors or inaccuracies that may appear in this document. Periodically, changes may be made to the information in this manual; these changes will be incorporated into new editions of this publication.
Content Disclaimer Copyright Notice Trademarks Content Manual introduction Symbol explanation Certification Notices Safety notices Contact information Intended use, intended users and operation of the device Intended use Intended users Operation of the device Usage of the device Risks and contra-indications Technical information Description Adjusting the arm swing, arm fitting and elbow fitting...
Page 4
Appendix 5 Troubleshooting guide Entering the troubleshoot mode Appendix 6 Declaration of conformity Appendix 7 Conditions and Warranty Conditions and Warranty: Gowing supplied through a representative of Focal Meditech Conditions and Warranty: direct supply by Focal Meditech BV to end users...
This is the user manual for Gowing , a dynamic arm support system. This product is developed, manufactured and distributed by Focal Meditech B.V. or one of its authorized representatives. This manual contains important information regarding Gowing , its intended use and possible consequences of usage.
Symbol explanation Symbols used in this manual This symbol in combination with the word “Danger” is used when there is important information which can help you avoid the risk of an equipment failure and serious personal injury or death. Danger This symbol in combination with the word “Warning”...
Certification Notices This is a CE Class I medical device Do not remove this label. If the label is removed, the warranty will be void. This label is positioned at the rear side of Gowing Do not remove this label. If the label is removed, the warranty will be void. This label is positioned at the bottom side of the Eneaswitch Do not remove this label.
Warning: Do not modify any part of this equipment without authorization of the manufacturer. Failure of this can lead to malfunctioning and will void the warranty. Warning: In case of faulty device contact Focal Meditech. Do not try to fix it yourself. Failure of this will void the warranty.
Intended use, intended users and operation of the device Intended use Gowing is a dynamic arm support system. It is designed for users requiring considerable compensation against gravity during movements of the human arm. Intended users The intended users of the dynamic arm support Gowing are users in the need of a function device requiring limited learning efforts: Persons challenged by considerable muscular weakness resulting in the inability to perform...
Gowing is not designed to able to cope with large forces. Gowing cannot be used as a support when standing up, sitting down or as an autonomous lifting device (without supporting the human arm). Gowing is not designed to withstand impacts that can be introduced during collisions with a wall or other objects.
Page 12
(wheel)chair. Do not try to fix it yourself but contact Focal Meditech or its authorized representative. Failure to do this will void the warranty.
Technical information Eject knob Load arm Elbow fitting Arm fitting Body Wrist support Indication LED On / off switch Power module Handle Rotation Tilt module Description The following parts of Gowing are described below: • From a user perspective the contact point with Gowing is the arm fitting where the forearm of the user is positioned in.
elbow fitting and wrist support. • Body of Gowing . The body of Gowing contains: the actuator for the lift function, the actuator to adjust the balance force and an actuator to operate the blocking mechanism for any up/down and forward/backward movement. •...
Page 15
Warning: Adjusting the arm fitting can result in a malfunction of Gowing Set screws arm fitting The arm fitting can be adjusted in one axis. Adjusting the position of the arm fitting is done in the following way: Loosen one or multiple set screws of the arm fitting. Adjust the arm fitting by shifting this fitting in the direction of the arrow.
Caution: The positions of the arm fitting and elbow fitting are crucial for the performance of Gowing . Changing these positions can result in a severe decrease of the performance or even malfunction of Gowing . Therefore only trained persons are allowed to change the settings of the arm fitting and elbow fitting.
Removing / mounting the Gowing Gowing can easily be removed from the Power module. Hand position 1 Hand position 2 Removing Gowing from the power module (right handed version) Set all settings to default. STEP 1: Remove the user’s arm from the arm fitting. STEP 2: Switch off Gowing STEP 3:...
Placing Gowing to the power module (right handed version) Hold the Gowing with your right hand on position 1 and your left hand on position 2. STEP 1: Hold the Gowing above and in a tilted position approximately 15° towards the Power STEP 2: module.
Page 19
Place to interact with connector To remove the power connector: hold the connector as close as possible inside the mounting base and turn counter clockwise the outer ring until it moves completely free. Then pull the connector out of the chassis part.
Controls Eneaswitch Gowing has a 9-button interface called Eneaswitch with LED indicators and a buzzer for user feedback. The functions are divided in three columns (see drawing below). The Eneaswitch easy to operate. The level of protection (Ingress Protection) is IP22. Even though the IP rating is at this level, care must be taken to not operate the silicone keypad with sharp objects.
plus or minus button is pressed when the system is locked the ring-LED will blink red and a double beep will sound Adjustment of the tilt function Buttons of the middle column The buttons in middle column are used for the tilt function. Gowing is able to adjust its position with respect to the gravity in the horizontal plane.
The longer the button is pushed, the faster the adjustment will be. The button Means lift the lever up and means lower the lever. If the lift has reached its end the ring-LED will blink red and a beep will sound. If the button is pressed when the system is locked the ring-LED will blink red and a double beep will sound Optional inputs on the Eneaswitch...
Single switch control Eneaswitch The single switch mode of Gowing allows the user to control the Gowing with only one switch. To control the Gowing in single switch mode there must be one external switch be configured as “Single switch”. The configuration can only be done by authorised people. The single switch control starts scanning after pressing the external button.
Accessories Battery pack and charger The battery pack can be used if there is no or not enough power to operate Gowing , for example on a working chair or manual wheelchair. The battery pack comes with a charger and a power cable to connect the battery pack to the power module.
10 of this manual. Installation of the Gowing needs to be executed by Focal or a certified professional that is approved by Focal Meditech or one of its authorized professional, to ensure a safe integration of the Gowing and the other equipment.
(DIN 912) with a minimum class of 8.8. The Power module should be mounted on a standard bracket. If the standard brackets do not fulfil the needs for the installation a custom made bracket can be made but this bracket should always need an approval by the R&D department of Focal Meditech. 6.00 THRU 10.50 38.50...
To reuse Gowing , it must be disassembled and reviewed by a professional from Focal or a certified professional that is approved by Focal Meditech or one of its authorized professionals. Gowing must intensively be cleaned and inspected. The keypad of the Eneaswitch can be removed and replaced by a new one.
Appendix 1 Technical specifications Gowing specifications Mass [kg] • Mass Gowing Dimensions (in default position) [mm] • Height [mm] • Width [mm] • Depth Mounting position(angle) -10...10 [º] • Maximum allowed Range of motion [mm] @ end of lever • Up/Down [mm] @ end of load arm •...
Page 29
Tilt function (Intergraded tilt module) -16...120 [º] • Angle [º] • Accuracy [º/s] • Speed Operation voltage • Nominal voltage Operation current (incl. Power module and Eneaswitch [mA] • Standby • During adjustments typical • During adjustments maximum Power consumption (incl. Power module and Eneaswitch •...
Power Module specifications (part of Gowing Mass • Mass Power module 0.135 [kg] Dimensions • Height [mm] • Width [mm] • Depth [mm] Mounting position(angle) • Maximum allowed -10...10 [º] Input voltage • Nominal input voltage • Absolute input voltage range 23...40 Input current •...
Page 31
Eneaswitch specifications (part of Gowing Mass • Mass Eneaswitch 0.122 [kg] Dimensions (with mounting clip) • Height [mm] • Width [mm] • Depth [mm] Cable length • Length 2445±20 [mm] Input voltage • Nominal input voltage Operation current • Standby [mA] •...
Gowing dimensions Dimensions of Gowing are variable. This is because it is a product with moving parts and it is a product with different configurations. All dimensions are given in [mm] millimetres. Dimensions (human interface excluded)
Content of case Gowing Place reserved for optional switches Place reserved for Human interface Eneaswitch Power module Gowing The case of Gowing contains the following parts: • Gowing • Power module • Eneaswitch • Battery power cable • Quick Start Guide Some parts are individual and are added on specifications but these depend on the user: •...
Appendix 3 Used materials Focal number Description Material(s) 605540 Subassembly Gowing Aluminium 6082T6 + stainless steel (AISI 304) 604782 Power module Aluminium 6082T6 605694 Case with inlay Gowing 605547 Eneaswitch 605868 Battery pack Aluminium 6082T6 + Li Ion battery 605893 Charger battery pack Aluminium 6082T6 605938...
Page 38
603137 Subassembly Elbow fitting left (Small) Aluminium 6082T6 + NEOPRENE 603143 Subassembly Elbow fitting right (Small) 603135 Subassembly Elbow fitting left (Large) 603141 Subassembly Elbow fitting right (Large) 603139 Subassembly Elbow fitting left (X-Large) 603145 Subassembly Elbow fitting right (X-Large) 603140 Subassembly Elbow fitting left (XX-Large) 603146...
Page 39
604190 Fixation strap complete Large NEOPRENE 604191 Fixation strap complete Small NEOPRENE 605926 Elbow bracket L shape short left Aluminium 6082T6 605927 Elbow bracket L shape short right Aluminium 6082T6 605683 Mobile stand...
Page 43
This is the Quick start guide for Gowing , a dynamic arm support system. This product is developed, manufactured and possibly distributed by Focal Meditech B.V. This quick start guide contains the basic information regarding Gowing . The aim of this information is to ensure successful, safe and effective use of the device.
Page 44
Overview / Overzicht Eject knob / Ejectschakelaar Load arm / Draagarm Elbow fitting / Elleboogsteun Arm fitting / Armschaal Body / Wrist support / Romp Polsondersteuning Indication LED / Indicatie LED On / off switch / Aan/uitschakelaar Power module Handle / Hendel Rotation / Tilt module / Kantelmodule Rotatie...
Page 45
Safety notices / Veiligheidsnotities Danger: Prevent direct contact with water or any other liquid. Failure of this can lead to malfunctioning of device or bodily harm. Gevaar: Voorkom direct contact met water of enige andere vloeistof. Het niet voorkomen hiervan kan leiden tot onjuist functioneren van het apparaat of tot lichamelijke schade.
Page 46
Focal Meditech. Warning: In case of a serious incident when using the device, contact Focal Meditech and the national authority of your country. Waarschuwing: Bij een ernstig voorval met betrekking tot dit apparaat dient contact te worden opgenomen met Focal Meditech...
Page 47
Switch on Gowing / Aanzetten Gowing On/off switch Indication led Figure 2: Picture of on/off switch with indication LED Figuur 2: Afbeelding van de aan/uit schakelaar met indicatie LED Before switching on Gowing , the Gowing has to be attached to the Power Module (See “Attach / Detach Gowing ”).
Page 48
Attach / Detach Gowing / Koppelen / ontkoppelen Gowing Hand position 1 Hand position 2 Figure 3: Indications of hand Figure 4: Rotate the red positions to detach Gowing handle upwards Figuur 3: Aanduiding van Figuur 4: Trek de rode handposities om Gowing hendel omhoog te ontkoppelen...
Page 49
Detach Gowing from Power Module (right handed version): Set all settings to default STEP 1: Remove the user’s arm STEP 2: Switch off Gowing STEP 3: Disconnect the human interface and store it in the case STEP 4: Place your right hand on position 1 and your left hand on position 2 STEP 5: (see Figure...
Page 50
Attach Gowing to the Power Module (right handed version): Grab Gowing with your right and on position 1 and your left STEP 1: hand on position 2 Hold Gowing above the Power Module in a tilted position of STEP 2: approximately 15°...
Page 51
Attach / Detach the human interface / Koppelen / ontkoppelen van de human interface Figure 7: Attach / detach human interface Figuur 7: Koppelen / ontkoppelen human interface The human interface containing the load arm, arm fitting, elbow fitting and wrist support can be removed easily. To detach the human interface, press both red eject knobs at the top of Gowing , and move the human interface away from the body in the upwards direction.
Page 52
Eneaswitch keypad control / Eneaswitch toetsen bediening Buttons of the left column Figure 8: Blocking function / adjustment of balancing force Figuur 8: Blokkeer functie / verstelling van balanceerkracht The left column contains the blocking function and the adjustment of the balancing force.
Page 53
Buttons of the middle column Figure 9: Adjust tilt angle of Gowing Figuur 9: Verstelling kantelhoek van Gowing The buttons in middle column are used for the tilt function. The button marked with will adjust the tilt module to the position where the rotating axis is set perpendicular to the gravity plane.
Page 54
Buttons of the right column Figure 10: Adjust tilt angle of Gowing Figuur 10: Verstelling liftfunctie van Gowing The buttons in the right column are used for the lift function of Gowing When pushing the button , the human interface will go to the lowest position.
Page 55
Eneaswitch Single switch control / Eneaswitch een-knops bediening The single switch mode of Gowing allows the user to control the Gowing with only one switch. To control Gowing in single switch mode there must one external switch be configured as “Single switch”. This can be only be done by authorised people.
Page 56
De bediening met één schakelaar begint te scannen na het indrukken van de externe knop. De functie die door de blauwe LED wordt aangegeven, wordt geactiveerd wanneer de externe schakelaar wordt ingedrukt. Bijvoorbeeld in Figuur 11 zal de blokkeer functie worden geactiveerd wanneer op de externe schakelaar wordt gedrukt.
Page 57
Contact information / Contact informatie Gowing is manufactured and sold by: Gowing wordt gefabriceerd en verkocht door: Focal Meditech BV Droogdokkeneiland 19 5026 SP Tilburg Netherlands Tel.: +31 13 533 31 03 Fax: +31 13 533 50 04 E-mail: info@focalmeditech.nl Internet: www.focalmeditech.nl...
Means previous error message and means next error message. If an error occurs, please contact Focal Meditech for assistance and provide the error message. To exit the error messages menu press the “lock” icon. To exit the configurations menu press the button of the right column.
Conditions and Warranty: direct supply by Focal Meditech BV to end users In the case of direct supply by Focal Meditech BV to end users, Conditions and Warranty are subject to the Consumer General Terms and Conditions issued by Koninklijke Metaalunie and in...