Convergence - Sony TRINITRON KV-HA21P50 Service Manual

Bg2t chassis
Table of Contents

Advertisement

3-2. CONVERGENCE

Preparation :
Before starting this adjustment, adjust the focus, horizontal
size and vertical size.
Receive dot/hatch signal.
Pic mode: Soft.
(1) Horizontal and Vertical Static Convergence
Center dot
R
G
B
R
G
B
H. STAT VR
C3 board
1. (Moving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the
center of the screen.
2. (Moving horizontally), adjust the H.STAT VR control so
that the red, green and blue dots are on top of each other at
the center of the screen.
3. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor
and the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjust-
ments while tracking.)
Purity
V.STAT
V.STAT
V.STAT Magnet
RV 702
BMC
BMC (Hexapole)
Purity
– 13 –
Operation of V. Stat magnet
If the V. Stat magnet is moved in the "a" and "b" arrows, the
red, green and blue dots move as shown below.
1
a
b
b
2
a
a
R
G
B
3
b
a
b
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned,
then use the BMC magnet to adjust in the manner described
below.
R G
B
R
G
R
B
R
G
G
KV-HA21P50
a
b
B
B
G
G
R
R
b
b
B
G
R
a
b
B
R
G
G
B
R
B
R
G B
B
G
R
B
RM-969

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron rm-969

Table of Contents