2. Installation

2.1 Installing or changing the lamp

WARNING: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
Light source: OSRAM HMI 575 GS
Position head in horizontal position. Hinge no. 1 must be on the
upper side of the head. Turn screws no. 5 1/2 turn left and remove
plastic lid.
Loosen knurled head screw no. 3 and open the lampcover.
Insert the lamp into the lamp holder. The nipple of the lamp
must face the top lid of the head. (See sketch).
If changing the lamp, remove old lamp from
lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb.

2.2 Powering the fixture

WARNING: To ensure propper installation of the plug consult a qualified
technician!
Install a 3-prong gounding type plug that fits your supply
Connected load: voltage 230V, frequency 50Hz
brown
blue
yellow/green gound
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
nipple
live
"L"
neutral
"N"
2
1
3