Jantar REX F-0-9 Manual

Standalone or access controller

Advertisement

Quick Links

REX F-0-9 – STANDALONE OR ACCESS CONTROLLER
The Rex is a controller with built-in fingerprint reader. It is
designed for residential and business buildings, offices, shops, etc.
In various operation modes, the controller allows access for up to
500 users (2 master fingerprints + 500 user fingerprints).
As a standalone controller, the entire set-up procedure is carried
out with the master fingerprint. User fingerprints can either be
registered or deleted.
As an access controller, the entire set-up procedure is carried out
with the software.
The controller signals normal operation with flashing red and green
LED. It can also be used as a Wiegand 26-bit reader, if needed.
TECHNICAL DATA
REX F-0-9
Current consumption
Operating voltage
Operating temperature
Communication
Dimensions (mm)
Sensor protection
Usage
Cabel
Mounting height
Memory
Inputs
Outputs
Inputs
Clock
CONNECTION CABLE
Description/Wiegand 26-
Wire-Color
bit
1 – Red
9-14V DC
2 – Gray/Black
GND
3 – Green
El. strike output / Data 0
4 – White
Alarm output/ Data 1
Door status switch input/
5 – Yellow
Buzzer input
Push button input /
6 – Orange
LED input
7 – Blue
CA
8 – Brown
CB
LED DIODES
Color
Flashing red/green
Lit green
Lit red
Black line
REX F-0-9– Standalone or Access Controller
50mA
From 9V to 14V DC
From -20°C to 60°C
RS485
58x120x17 (WxHxD)
> 15kV ESD protection
> 1 million wear cycles
Cable through or on the wall
– 3m
140cm from the ground
500 fingerprints
500 events
Door status
Push button
Transistor output for el.
strike 0.5A
Door status
Push button
Real time clock, battery
backup (max. ten hours)
Specification
Power supply
Ground
Max. 0.5A
Active = GND
Active = GND
Active = GND
Active = GND
RS485 A line
RS485 B line
Description
Normal mode
El. strike is unlocked
Fingerprint has no rights
Power supply
The controller need's external power supply to operate. The
Spider W40 power supply is sufficient to power two controllers and
two 12V electric strikes or two 12V magnetic locks (0.5A). If you
will use it as a standalone controller and low consumption electric
strike (0.25A) you can use power supply Spider W5.
Voltage drops and cable signal interferences
When you connect the controller, use cable with a diameter of at
2
least 0.22mm
. If the cable length exceeds 25m, use one twisted
pair of UTP cables for the positive (+) pole and one for the
negative (-) pole. The cable length between power supply and the
controller should not exceed 50m.
Take into consideration that a 0.22mm
approximately 9 ohm per 100m. The power supply at the end of
cable should be a minimum of 9V. If you are using el. strike, it is
highly recommended that the voltage drop is calculated. At greater
distances, a thicker cable of 0.5mm
wherever possible.
If the load is, for example, 0.5A (with el. strike) then, on the
2
0.22mm
cable voltage drop will be 4.5V at 100m. For the device
with 60mA consumption, the voltage drop is 0.5V.
Inputs, outputs and environment
Inputs:
Inputs are realized with opto-isolators. The input is active, when
pulled to ground with an open collector transistor or mechanical
switch, which is connecting the input pin of the controller to the
Ground.
Outputs:
Output has a pre-installed protection diode for an inductive load. It
is also protected from current overload. The best way is to use a
0.25A el. strike or a 0.5A el. magnet, which has to be connected to
the same positive pole (+) as the controller. Connect the negative
pole (-) to the door strike output (wire 3). When the output is
active it is pulled to ground. This can be changed with function 5 –
negate output (for el. magnet).
Environment:
It is designed for indoor, non-condensing, applications. Do not
expose the controller to direct contact with the elements such as
rain, snow or sunlight.
If the plastic housing is in a different color
than black, then there is a chance that the color will change (to
some extend) in a few months or years if exposed to direct
sunlight.
The sensor surface is hard and extremely robust, and will
withstand years of normal wear-and-tear. Do not subject the
sensor to sharp or hard objects since this might cause permanent
damage. Cleaning should be done with a lint-free cotton textile. Do
not subject the sensor surface to mechanical force.
You must assure good cable joints, protected against moisture,
otherwise corrosion may damage the controller. Damage in such
cases is not covered by the warranty.
Installation of Rex F
Remove black plastic screw covers on the top and the bottom of
the controller. Install the controller to the wall with two supplied
screws. Use diagonal holes - it enables a small correction of the
position of the controller (up, down, left, right). When the
controller is installed, put the screw covers back on.
2
cable has a resistance of
2
or more should be used
3/2015
www.jantar.si

Advertisement

Table of Contents
loading

Summary of Contents for Jantar REX F-0-9

  • Page 1 . If the cable length exceeds 25m, use one twisted pair of UTP cables for the positive (+) pole and one for the REX F-0-9 – STANDALONE OR ACCESS CONTROLLER negative (-) pole. The cable length between power supply and the controller should not exceed 50m.
  • Page 2 REX F-0-9– Standalone or Access Controller AS A STANDALONE CONTROLLER one, controller confirms the successful registration with a lit green LED and activated output. If the registration has failed the controller signals with a longer beep. If the registration is...
  • Page 3: Specification

    REX F-0-9– Standalone or Access Controller Function 6) Delete a fingerprint Turn on/off the accelerometer which triggers the alarm output Delete the next fingerprint on the list. Use this function if you wish (output1, O1, wire 4) when the controller is moved.
  • Page 4: Ordering Codes

    Spider W5-USB, Spider W5-NET, Spider W40+NET. The RS485 communication bus is used between the controllers and Jantar software. Up to 128 controllers can be lined up into one communication line. The maximum length of the communication line is 1000 cable meters. It is recommended that you use an FTP or S-FTP cable.
  • Page 5: Technical Data

    RS485 B line (up, down, left, right). When the controller is installed, put the screw covers back on. LED DIODES Color Description Flashing red/green Normal mode Lit green El. strike is unlocked Lit red Fingerprint has no rights 3/2015 Black line www.jantar.si...
  • Page 6 When you hear the required number of beeps, approach a user card For registration or deletion of user fingerprints and cards you can use the or place a user fingerprint on the sensor for confirmation. master fingerprint or card. 3/2015 Black line www.jantar.si...
  • Page 7 Time is set in seconds 4. beep Sound is OFF Tamper is OFF Door status switch input-normally closed (NC) Time is set in seconds 3/2015 Black line www.jantar.si...
  • Page 8 Spider family: Spider W5-USB, Spider W5-NET, Spider W40+NET. The RS485 communication bus is used between the controllers and Jantar software. Up to 128 controllers can be lined up into one communication line. The maximum length of the communication line is 1000 cable meters. It is recommended that you use an FTP or S-FTP cable.